Be aware that walls (or surfaces) with differing material
structures, or even variations in material composition,
can cause measurement results to be falsi
Ö
ed.
Perform
multiple comparative measurements
. Wait until
the % symbol stops blinking and remains constantly
lighted. Only then are measurement values stable.
The location to be measured should be untreated,
free of knots, dirt and resin. Measurements should
not be made on the end faces of wood because
these areas dry particularly quickly such that they
produce incorrect measurement results.
Perform
multiple comparative measurements.
Wait until
the % symbol stops blinking and remains constantly
lighted. Only then are measurement values stable.
Mineral building materials
Wood
Be sure neither supply lines (electric lines, water pipes, etc) nor a metal subsurface is present at the location to
be measured. Insert the electrodes as far into the material as possible but never use excessive or sudden impact
force as this could damage the device. Always pull the device out of the material with left/right twisting motion.
Perform several comparative measurements at different locations
to minimise measurement error. The
sharply pointed electrodes present an
injury hazard
. Always put the safety cap on the device when it is not in
use or being transported.
Measuring material moisture
Just which building materials are grouped under 01 to 04 can be found in the table in Section 11.
Select building material (01, 02, 03, 04)