ActiveMaster
13
Voltage test
3
Functional test/Self-test
2
• Test the voltage tester by applying it to familiar voltage
sources
• Connect test prods (1) and (2). The LED for the continuity
test (8) lights up and a signal sounds.
• Press the „AUTOTEST“ button. If the test is successful,
all the LEDs (4) light up along with the LED for the continuity
test (8) and a signal sounds.
• The voltage tester is activated automatically at voltages
of 12 V or above and indicates the measured voltage by
lighting up the relevant LED (4).
Hold the base device (+)
in your right hand and the
second test prod (-) in your
left hand. Now apply the test
prods to the contacts to be
tested (line, socket, etc.).
To achieve the protection class CAT III 1000 V and
CAT IV 600 V the protective covers (14) must be placed
over the test prods.
!
Test prod -
Test prod +
Flashlight
LEDs for indicating
the voltage
LED for single-pole
phase test
Voltage warning > 50V
LED for clockwise (L) /
anticlockwise (R) rotating
field
1
2
3
4
5
6
7
LED for continuity
Self-test
Flashlight ON/OFF
Battery compartment
LED for +DC voltage
LED for -DC voltage
8
9
10
11
12
13
LED for AC voltage
12 + 13
Schutzkappen für CAT III
1000 V / CAT IV 600 V
14
Device description
(see Fig. F)
EN
Summary of Contents for AC-tiveMaster
Page 52: ...52...