MultiMeter-Home
17
6
7
X10
Ω
X1k
Ω
0
Ω
- 1 k
Ω
0
Ω
- 1 k
Ω
x 10
x 1000
Result
Scale
Measuring
range
Resistance measurement
To measure resistance, set the rotary switch to the “Ω” position
with the corresponding measuring range (X10Ω - X1kΩ).
Before each measurement, check that the pointer is set exactly
to „0“ on the OHM-scale (A). Hold the two test prods so that they
touch and, if necessary, adjust the pointer with rotary knob (3).
Then connect the measuring contacts
to the object to be tested.
Reading the scale (A):
green
orange
red
Good: battery
fully charged
Weak: battery is weak
and will soon need
replacing
Replace: battery
is flat and should
be replaced
Battery charge status
Colour
BAT. Battery charge status measurement
To measure the battery charge status, set the rotary switch to
the “
BAT.
“ position with the corresponding measuring range.
1.5 V round cells / AA, AAA, C, D
9.0 V flat cells / E-block
Then connect the measuring contacts
to the battery.
3-colour display scale (D):
red
black
GB