The main control unit is equipped with a service display and two push-
buttons. It enables to display and adjust some parameters of the device.
WARNING!
The irresponsible use of the settings can seriously limit the performance
of the device.
Parameter FACTORY SETTINGS
“
”
Parameter “CUSTOM SETTINGS” if one or more parameters are
adjusted in a different way from factory.
ENTRY PROCEDURE FUNCTION
By long push (longer than 2 seconds) of whichever button, activation of
service state occurs. Display shows number of chosen parameter.
Choose desired parameter by means of buttons - down by left button, up
by right button. At the same time you will also have a graphical indication
that shows the area where you are working.
By long push (longer than 2 seconds) of whichever button value of
chosen parameter is displayed. Value is blinking.
Change the value of parameter by means of buttons down by left
-
button, up by right button.
By long push longer than 2 seconds of whichever button new value is
(
)
stored and number of chosen parameter is again displayed.
IMPORTANT
: confirm
to
the changes made, remove and reinsert the
reverse gear, then wait at least seconds.
2
FACTORY SETTING RESTORING
In order to restore default parameters to the factory setting, simply enter
programming functions, hold down any button for more than 5 seconds, after which,
press and hold BOTH buttons on the unit (RIGHT LEFT BUTTON) until
the display shows “
”.
FS - FACTORY SETTING
ENTRY PROCEDURE FOR ADJUSTMENT OF PARAMETERS