background image

 

NOTES 

Summary of Contents for 4003-0000-U

Page 1: ...3 1041 Rev 2 28 19 VERTICAL CONTROL LASER OWNERS MANUAL 1810 SE First Street Suite H Redmond OR 97756 Phone 541 548 0882 Fax 541 548 0892 Email laserline laserline net Website www laserlinemfg com Rev 3 11 19 ...

Page 2: ...1000HDU laser 2 Alignment Targets P N 4001 0010 Ultra bright bulls eye for the most visible and precise readings at any distance Targets feature laser pass through allowing multiple readings at one time special hard coating that protects the graphics on the target face and two inch holes for custom mounting Carrying Case P N 3000 0182 Blow molded custom fit foam inserts and two locking latches for...

Page 3: ...or the purpose of providing plumb control for your project It also features a short range downward shooting laser beam that is used like a plumb bob or optical tribrach to easily get directly over your point The Quad 1000HDU is a self leveling instrument with electronic temperature compensation It measures or senses ambient temperature changes while in operation and continually recalibrates itself...

Page 4: ... the Quad has self leveled to within its operating spec the plum bob laser comes on steady and the long range upward Zenith shooting laser beam is activated Self leveling time is normally under ten seconds After five minutes has elapsed the downward shooting plumb bob laser automatically shuts off to save battery power If at a later time you want to check to see if you are over your point just pus...

Page 5: ...he duration of the job Do not move the Quad 1000HDU up from floor to floor as the building progresses This can create compounding errors USING THE TRIVET MOUNT This is the preferred method It keeps the instrument low to the deck and closer to your reference point Also since the unit is only inches off the ground it won t be so vulnerable to getting knocked over like with a tripod A Attach the Quad...

Page 6: ...the target center that allows the center of the laser spot to pass through so that more than one target can be used at the same time E There are two mounting holes in each target to allow for custom mounting at the job site 500 ft 152m 0 80 2cm 1000 ft 305m 1 10 2 8cm WARNING Turn the laser OFF when centering up on the alignment target with an optical plummeted instrument Transferred points from f...

Page 7: ...or 1 8 at the target per 100 vertical feet If you are not comfortable or confident with the field calibration check have it checked by your Dealer Service Department MAINTENANCE The Quad 1000HDU requires no maintenance other than periodically cleaning the laser output lens Use a soft cloth with Windex or alcohol NOTE Laser must be turned OFF when cleaning the lens CERTIFICATION USA EN IEC 60824 1 ...

Page 8: ...Identification and Certification Non Interlocked Warning Label Top Explanatory and Warning Label Hazard Symbol Aperture Label Bottom LABELS Required for this product Aperture Label Top ...

Page 9: ...USA EN IEC 60824 1 2007 Class 3R International IEC 60825 1 2014 Class 3R USA OSHA compliant Meets all Federal and International standards Power source 12 VDC or 110 220 VAC with optional 1140 power converter Operating temperature 0 to 122 degrees F 18 to 50 c Storage temperature 4 to 158 F 20 to 70c Dimensions Height 8 20 32cm Width 6 x 6 16 50x16 50cm at bottom Width Handles Side 9 23 6cm Weight ...

Page 10: ...t always check for accuracy per the enclosed instructions in this manual Warning Under no circumstances attempt to open or disassemble the Laser Housing Doing so may cause exposure to potentially hazardous levels of laser light Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure Factory Service Center La...

Page 11: ...NOTES ...