background image

4

5

Audible Continuity:

1.  Remove covers from test probe tips, insert black test lead into COM socket (

J

) and red 

test lead into VΩ RPM (Multifunction) socket (

I

).

2.  Set the Function / Range rotary switch (

F

) to the Ω position, press the function/ selection 

button (

D

) to display the       symbol. The polarity of the red test lead is positive.

3.  Touch the test probes to the wire or circuit you wish to check. If the wire or circuit has 

continuity, the audible signal will sound. If there is no continuity (open circuit) the display 

will show OL.

(

Caution

: Risk of electric shock. Never measure continuity on circuits or wires that have 

voltage on them).

Frequency Measurement:

1.  Remove covers from test probe tips, insert black test lead into COM socket (

J

) and red 

test lead into VΩ RPM (Multifunction) socket (

I

).

2.  Set the Function / Range rotary switch (

F

) to 320Hz, 3200Hz, or 32kHz as applicable.

3.  Connect the test leads and read the frequency value displayed.

Measuring Temperature:

Note: Although the multimeter is rated for -20ºC to 750 ºC and -4ºF to 1382ºF, the K type 

thermocouple supplied with the multimeter is only rated to 250ºC. To measure temperatures 

outwith that range, a higher rated professional thermocouple is required.

1.  Set the Function / Range rotary switch (

F

) to 1400ºF or 750ºC. The F or C symbols will be 

displayed and the display will show the ambient temperature.

2.  Connect the black plug of the K type thermocouple to the into COM socket (

J

) and red 

plug into VΩ RPM (Multifunction) socket (

I

).

3.  Touch the thermocouple probe to the object to be measured and read off the temperature.

(Caution: Risk of electric shock. Ensure that the thermocouple has been removed before 

changing to another function / measurement).

Dwell Angle Measurement:

On conventional contact breaker type ignition systems, the dwell angle is the number of 

degrees (º) through which the distributor cam rotates while the breaker points are closed.

1.  Remove covers from test probe tips, insert black test lead into COM socket (

J

) and red 

test lead into VΩ RPM (Multifunction) socket (

I

). 

2.  Set the Function / Range rotary switch (

F

) to the to the desired DWELL range according 

to the number of cylinders on the engine to be measured.

3.  Connect the black test lead to car battery negative (ground) or chassis, and the red test 

lead to the distributor side terminal of the ignition coil.

4.  When the engine is started the dwell angle will be displayed.

Note: To reduce the dwell angle reading the points gap must be increased; to increase the 

dwell angle the points gap must be reduced. Refer to the owner’s handbook, workshop 

manual or other manufacturer’s documentation for detailed procedures for dwell settings 

and adjustments.

Duty Cycle:

1.  Remove covers from test probe tips, insert black test lead into COM socket (

J

) and red 

test lead into VΩ RPM (Multifunction) socket (

I

). 

2.  Set the Function / Range rotary switch (

F

) to the DUTY position.

3.  Connect the negative (black) test probe tip to earth (ground).
4.  Connect the positive (red) test probe tip to the signal wire circuit (for example, a fuel 

injector or fuel mixture control solenoid).

RPM (Tachometer) Measurements:

1.  Remove covers from test probe tips, insert black test lead into COM socket (

J

) and red 

test lead into VΩ RPM (Multifunction) socket (

I

). 

2.  Set the Function / Range rotary switch (

F

) to either the RPM or x10RPM position.

3.  Connect the black test lead to car battery negative (ground) or chassis, and the red test 

lead to the distributor side terminal of the ignition coil.

4.  Start the engine. Divide the displayed reading by the number of cylinders of the engine. 

On x10RPM position, also multiply the displayed reading x 10 to get the actual RPM.

General Specifications:

Polarity:  

 

Auto polarity indication.

Over range indication: 

OL on digital display.

Auto zeroing function 
Sampling rate: 

 

3 times per second (approximately).

Operating temperature: 

0º - 40ºC

Storage temperature: 

-10º - 50ºC

Battery:   

 

single 9V.

Low battery indication: 

(Refer to diagram: symbol C on display).

Auto power-off: Automatically turns off if no control is operated for 10 minutes. Beeps to 

warn of auto power-off. Press hold button (

E

) to reactivate.

Range

Resolution

Accuracy

326mV

0.1mV

+/- (0.5% + 5)

3.26V

1mV

+/- (0.8% + 5)

32.6V

10mV

+/- (0.8% + 5)

250V

0.1V

+/- (0.8% + 5)

DC Voltage (autorange):

Input impedance:  

10MΩ (for 326mV range: >100MΩ

Overload protection: 

250V DC/AC

Reviews: