Laser Reference ProShot L5 Operation Manual Download Page 8

Applications

6

Safety

Precautions that should be followed when using any laser.

• Don't stare into the laser beam or view it directly with optical 
   instruments.
• Don't disassemble the laser or attempt to service it.
• Don't use the laser until you have read the instruction manual 
   and you are familiar with how to operate the laser properly.

U.S. OSHA requirements for operating visible lasers.

• Only qualified and trained employees are to install, adjust and operate
   the laser.  (see operator card included with this manual)
• Laser operators must carry proof of qualification.
• The area of a job site where a laser is being used must be posted with
   a laser warning placard (included with shipments to U.S. & Canada).
• The laser should be set up above eye level and never intentionally
   aimed at anyone.
• Turn the laser off when it is not being used, such as during lunch hour,
   at the end of the day, or during other long breaks in the work.

  
Note:  The L5 transmitter is a class IIIa (less than 2.5mW) laser under 
the United States C.D.R.H. guidelines.

    

The L5 is a class IIIa laser under the 1993 IEC 825-1 laser safety 
standard and the revised edition of the European Norm EN60825.  

   

The L5 conforms to applicable EC directives regarding RFI and EMI.

The L5 complies with FDA performance standards 21 CFR subchapter J.

A laser warning placard is included with 
lasers shipped to the U.S. and Canada.  
It may be attached to the carrying case 
- with the case visible and placed near 
where the laser is being used - for 
meeting job site posting requirement.

11

CAUTION

LASER LIGHT - DO NOT STARE

INTO BEAM OR VIEW DIRECTLY

WITH OPTICAL INSTRUMENTS

MAXIMUM POWER < 2.5mw

AT 630-650nm

CLASS IIIa LASER PRODUCT

Level Alignment 

  

The L5 Provides a precise reference               
for level alignment needs such as:

•  Setting concrete forms

•  Grading and landscaping

•  Digging footers and basements

•  Checking and leveling floors  

•  Soffets and cut-offs 

•  Plug and switch heights

•  T-bar ceilings

Vertical Alignment (see opposite page)

Along with its ability to project a level reference plane, the L5 has a built-
in manual vertical vial.  When the L5 is in the vertical position, the vertical 
vial located under the window in the control panel is used to plumb the 
rotatable beam of laser light.  When the  plane can be used for:

•  Aligning bolts and wall plates

  

•  Layout work

•  Plumbing walls and panels

•  Transferring lines from floor to ceiling

•  Aligning and plumbing posts and tall forms

Plumb Spot

The L5 projects a laser spot from the top 
of the rotating head that can be used for:

  

•  A reference beam at 90

º 

to the rotatable 

beam to assist with layout tasks.

•  A self plumbed beam for very accurately 
transferring points from floor to ceiling.

Summary of Contents for ProShot L5

Page 1: ...number _____________________________ Receiver S N __________________________________ Date of purchase _______________________________ Toll Free USA Telephone Fax Web Email 1 800 238 0685 1 408 370 4929 1 408 866 0858 www proshotlaser com sales proshotlaser com V 1 1 moved contact info all to back page moved contants to inside front cover L5 D I G I T A L ...

Page 2: ...zed service centers If service is needed the product s must be sent FREIGHT PREPAID to the nearest authorized service center or to Laser Reference L5 Transmitter Specifications 17 Contents System Contents And Battery Installation 1 Controls and Displays 2 Initial Setup Guidelines 4 Maintenance 5 Safety 6 Level Setup 8 Plumb And Layout Setups 9 Vertical And Line Layout Setup 10 Accessories Receiver...

Page 3: ...rcle The laser only works at short distances Check the output window on the rotating head of the laser for heavy dust or moisture Remove dust with a camera brush or blow off gently with clean compressed air Allow moisture to dry The receiver does not indicate on grade at long distance Be sure you have not exceeded 330ft 100m from the laser Check the output window on the rotating head of the laser ...

Page 4: ...rew will make approximately a 3 4 19mm change at 100 30m turn the screw only as much as it will take to correct any error observed in step 7 After making the adjustment remove the laser from the platform and give it two vertical shakes to center the compensator Adjusting calibration pushes on the pendulum of the compensator and can cause it to take a set The shaking procedure will relieve any set ...

Page 5: ... between these two marks is true level Make a long level mark at true level If the difference between either outer mark and true level is within your working tolerance go on to step 8 If not continue with the next step 14 Controls And Displays 1 Circular level vial The circular vial indicates if the laser is rough leveled closely enough for the automatic compensator to take over and maintain a pre...

Page 6: ...your work as possible Maintain your equipment Keeping tripod and mounting hardware tight and being sure grade rods are in good condition can prevent errors and performance problems Accessories Aluminum Tripod The model T2 adjustable aluminum tripod provides a stable platform for outdoor or indoor work Allowing a beam height from approximately 4 feet to 6 feet above the surface it rests on the T2 i...

Page 7: ...aces of the laser with a soft damp cloth Tripod mounting thread Occasionally the threaded hole for the tripod bolt should be lubricated with a light oil Caution Never store the laser in a carrying case that is wet inside Moisture can get inside the laser this way Should this happen remove the battery cover and place the laser and the open case in a warm area until it is completely dry free of cond...

Page 8: ...5 complies with FDA performance standards 21 CFR subchapter J A laser warning placard is included with lasers shipped to the U S and Canada It may be attached to the carrying case with the case visible and placed near where the laser is being used for meeting job site posting requirement 11 CAUTION LASER LIGHT DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAXIMUM POWER 2 5mw AT ...

Page 9: ...ting on should be reasonably level Turn the laser on and stop the beam rotation using the button Turn the rotating head to project the beam downward toward your near point while you rough align the assembly Turn on the rotation while keeping the beam on the near point and sliding the base of the assembly until the receiver s audio tone begins The X axis leveling knob now near the top of the laser ...

Page 10: ...f these setups attempted by contractors with predictably poor results Using the two leveling knobs center the bubble in the circular level vial review the procedure on page 2 if you have difficulty Facing the laser control panel and looking down at the circular level vial when you turn either leveling screw clockwise the bubble will move toward that leveling screw Once the bubble is centered start...