24
8. Rotate grade knob until sensor is bottomed out.
9. Replace roll pin in tension spring.
10. Adjust counter plate alignment.
a. Loosen counter plate screws.
b. While turning the grade knob, tilt the counter plate until a smooth
feel is achieved.
c. Tighten screws.
11. Replace lead screw gear
12. Adjust counter position.
a. Position counter with top aligned with top of counter plate.
b. Tighten upper screw enough to hold counter in place.
c. Shift counter over until gears mesh with minimal backlash and no
binding.
d. If sensor operates backward, reverse positions of the two leads
coming from the top of the sensor assembly.
13. Adjust slope axis grade alarm deadband (see procedure # 108)
#106
X-Axis Sensor Removal and Replacement
Tools required:
1/4" socket driver
Time:
Broad tipped Phillips driver
.5
Soldering iron
Phillips screwdriver
FIG. 6
(inside end)
Cross Sensor Mounting (outside end)
Summary of Contents for pro shot L1-M
Page 1: ......
Page 3: ......
Page 6: ...3 External Parts Detail Model L1 M Fig 1 ...
Page 7: ...4 External Parts Detail Model L1 S Fig 1A ...
Page 8: ...5 Internal Parts Detail Model L1 M Fig 2 10 0495 LCD assembly ...
Page 9: ...6 Internal Parts Detail Model L1 S Fig 2a ...
Page 10: ...7 Housing Lighthouse Model L1 S ...
Page 11: ...8 Motor Problems Model L1 M Only ...
Page 12: ...9 Motor Problems Model L1 S Only ...
Page 13: ...10 Power Problems ...
Page 15: ...12 Calibration Problems ...
Page 16: ...13 Calibration Problems 2 ...
Page 17: ...14 Calibration Problems 3 ...
Page 18: ...15 Low Battery Indication Not cured with new Batteries ...
Page 38: ...35 PCB Layout ...
Page 39: ...36 Schematic for L1 M S ...
Page 41: ...38 ...