background image

 

 

 

Instructions and Maintenance Sheets 

Electric Test Pump “HEP0180”

 

WARRANTY 

LARZEP,  S.A.

  guarantees  its  products  against  all  design  and  manufacturing  defects  for  two  years  from  the  date  of 

purchase.  This guarantee  does not include the ordinary wear of both metal and  non‐metal parts, abuse, using the 
equipment beyond its rated capacity and any wear or damage incurred as a result of using a hydraulic fluid which is 
not recommended by 

LARZEP, S.A. 

Please note that if the equipment is disassembled or serviced by anyone other than an authorized service dealer or 
by 

LARZEP, S.A

., this guarantee is rendered null and void. 

In the event of a warranty claim, return the equipment to 

LARZEP, S.A

. or the authorized dealer which sold you the 

hydraulic  equipment. 

LARZEP,  S.A

.  will  repair  or  replace  the  faulty  equipment,  whichever  is  deemed  most 

appropriate. 

LARZEP,  S.A.

  shall  not  be  held  liable  for  any  consequential  damages  or  losses,  which  may  occur  as  a 

result of faulty equipment. 

 

BEFORE USING THE EQUIPMENT AND ESSENTIAL SAFETY REQUIREMENTS 

 

This Electric test pumps HEP0180 has been designed for pressurizing and testing hydraulic systems and for filling 
and pouring operations. Maximum working pressure: 180 bar.  

 

The pump can work with clean water, water solutions, light oils and non‐aggressive liquids with a neutral PH. 

 

Read the instruction manual carefully and practise using the equipment before application. 

 

Always use protective goggles, shoes and gloves.

 

 

All pumps are tested individually, are tough and very robust and therefore very safe. 

 

Body of the pump made of brass. 

 

Do not modify the pump (welded parts,  etc.). 

 

Use the handles on the pump for transporting the device. Do not use the hose or pipe.  

 

Never  exceed  maximum  working  pressure  of  the  pump.  Ensure  that  all  the  equipment  and  accessories  are 
suitable for the maximum working pressure. 

 

Never turn on the pump when the pump is not connected to the plant. 

Do not pressurize the pump without being 

connected to an item to be pressurized unless a blanking plug is fitted to the outlet port.  

 

Never tighten or loosen connections while they are under pressure. 

 

Check that there are no damages on the pump. If there are worn or damaged pieces, replace them immediately.  

 

Respect electrical safety requirements: any operation must be performed by qualified personnel, only when the 
machine is disconnected from power. Replace any electrical components if damaged. Keep dry any electric part.

 

 

Before starting operation, check that the installation is correct, the operator position is safe and the working zone 
is out of bounds to all personnel. 

 

In all cases, the operator should have received adequate training regarding the handling of the device and logical 
safety criteria associated with the movement of heavy loads. 

 

TECHNICAL FEATURES 

Dimensions 

500 x 500 x 750 mm 

Weight 

66 kg 

Working Pressure 

180 bar 

Flow Rate 

13 l/min 

Outlet Port 

3/8” BSP Male 

Tank 

100 litres 

Motor 

400 V ~ 50 Hz Three‐phase 

Power 

5 kW – 2.800 rpm 

Summary of Contents for HEP0180

Page 1: ...V01 2019 INSTRUCTIONS MAINTENANCE SHEET ELECTRIC TEST PUMPS HEP0180 LARZEP S A Avenida Urtiaga 6 48269 Mallabia Spain Tel 34 943 171200 Fax 34 943 174166 e mail info larzep com www larzep com ...

Page 2: ...2 Instructions and Maintenance Sheets Electric Test Pump HEP0180 DECLARATION OF CONFORMITY ...

Page 3: ...uipment before application Always use protective goggles shoes and gloves All pumps are tested individually are tough and very robust and therefore very safe Body of the pump made of brass Do not modify the pump welded parts etc Use the handles on the pump for transporting the device Do not use the hose or pipe Never exceed maximum working pressure of the pump Ensure that all the equipment and acc...

Page 4: ...pment to test pipe tank valve etc 8 Before operating the pump always make sure pipe connections are clean and fully tightened up all accessories must be fitted correctly suction tube with nut and filter pressure gauge and hose for high pressure Always use protective goggles shoes and gloves 9 Verify that electrical requirements of the motor are according to the electric power supply in the plant T...

Page 5: ... for damaged gaskets and rings High humidity may cause this inconvenience Water leaking from the head Change damaged gaskets and rings Oil leaks replace oil gaskets Motor Hum Turn off the motor immediately and verify if the pump is not blocked Check if the voltage in the electric net corresponds with the data label Remember that long power cords may cause voltage losses Verify voltage at the pump ...

Reviews: