 PROBLEMS 

POSSIBLE FAILLURES 

SOLUTION 

1. The piston does not advance. 

- Prime fewer pumps. 

1. Feed the pump keeping it started some minutes. 

 

- Dirty accumulated in the filter. 

2. Extract and clean it. 

 

-No oil in the reservoir. 

3. Check the level. 

 

- Cylinder pressure retainer damaged. 

4. Replace the retainer. 

 

-Directional valve damaged. 

5. Replace the valve.

 

 

- Cylinders body damaged. 

6. Repair the body of the cylinder. 

 

- Pneumatic problem. 

7. Check the installation. 

2. The cylinder does not reach pressures. 

- Pressure relief valve unrated. 

8. Rate the valve. 

 

- Cylinder pressure retainer damaged. 

See Solution. 4. 

 

- Cylinders body damaged. 

See Solution. 6. 

3. The cylinder does not maintain pressure. 

- Cylinder pressure retainer damaged. 

See Solution. 4. 

 

- Directional valve damaged. 

See Solution. 5. 

4. The cylinder does not retract. 

- Damaged return spring. 

9. Replace the spring. 

 

- Directional valve damaged. 

See Solution. 5. 

                   

The solutions marked in black must be carried out by specialized personnel, for it, go to an authorized distributor that sold you the equipment or to LARZEP, S.A., 
we have original spare part kits as well as the necessary personnel, do not doubt in contacting to us, we are to yours disposition. 
 
Always use original spare parts LARZEP, you will extend the life utility of the equipment, in opposite case the company will not become person in charge of the 
possible failures, damages or losses that take place. 
                                               

 

6. WARRANTY. 

 

LARZEP, S.A.

 guarantees its products against all design and manufacturing defects for the durations of two years from the date of purchase. This guarantee does not 

include the ordinary wear of both metal and non-metal parts, abuse, using the equipment beyond its rated capacity and any wear or damage incurred as a result of 
using a hydraulic fluid which is not recommended by 

LARZEP, S.A. 

 

Please note that if the equipment is disassembled or serviced by anyone other than an authorized service dealer or by 

LARZEP, S.A

., this guarantee is rendered null 

and void. 
 
In the event of a warranty claim, return the equipment, to 

LARZEP, S.A

. or the authorized dealer which sold you the hydraulic equipment, 

LARZEP, S.A

. will 

repair  or  replace  the  faulty  equipment,  whichever  is  deemed  most  appropriate. 

LARZEP,  S.A.

  shall  not  be  held  liable  for  any  consequential  damages  or  losses, 

which may occur as a result of faulty equipment 

 

 
 
 
 

 
 
           
 
 
                   
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ECE02015

Page 1: ...V01 19 BENCH PRESS 20 ton WITH ELECTRIC PUMP ECE02015 CE LARZEP S A Avenida Urtiaga 6 48269 Mallabia Spain Tel 34 943 171200 Fax 34 943 174166 e mail info larzep com www larzep com ...

Page 2: ... in the equipment The hydraulic equipment must not be exposed to temperatures greatest than 60ºC as on use as on storage If you are purchasing a cylinder or pump for the use of it in the press make sure that you are using a correct combination before assembling it We recommended asking for advice in this questions to our technicians When a place to the press is located make sure that there is in a...

Page 3: ... green button of the panel of button and the motor stops when we push the red button o Only the general selector located in the electric cabinet allows the alimentation of the electric organs of the machine o The construction of machine has been calculated to bear without any breaking under conditions of foreseen utilization and for the whole life of the machine The hydraulic components have been ...

Page 4: ... both cases to maintain the movement it is necessary to keep pushed the button 6 With no material in the press repeat the movement of advance reaching the end of the stroke of the cylinder In this moment the pressure will go increasing so the gauge will read the pressure This pressure will go increasing until reach the maximum pressure of the installation previously chosen The cylinder maintains t...

Page 5: ...r to LARZEP S A we have original spare part kits as well as the necessary personnel do not doubt in contacting to us we are to yours disposition Always use original spare parts LARZEP you will extend the life utility of the equipment in opposite case the company will not become person in charge of the possible failures damages or losses that take place 6 WARRANTY LARZEP S A guarantees its products...

Page 6: ...6 Instruction Manual Bench Press with Electric Pump ECE02015 CE 7 DECLARATION OF CONFORMITY ...

Page 7: ...7 Instruction Manual Bench Press with Electric Pump ECE02015 CE ...

Page 8: ...8 Instruction Manual Bench Press with Electric Pump ECE02015 CE ...

Page 9: ...HEME LEYENDA DESCRIPCION Q1 CONTACTOR F1 RELÉ TÉRMICO M1 MOTOR S1 SELECTOR 0 1 F2 FUSIBLES T1 TRANSFORMADOR T2 RECTIFICADOR S2 PULSADOR PARADA S3 PULSADOR MARCHA S4 PULSADOR SETA DE EMERGENCIA S5 PULSADOR UP S6 PULSADOR DOWN Q2 ELECTROVÁLVULA BY PASS Q3 ELECTROVÁLVULA A Q4 ELECTROVÁLVULA B ...

Reviews: