L’ARTISTICO SRL |
31
Cod. 40297 | Rev. 09 | 05/2021 |
EN
Press and hold for
about 3 seconds
After some 10 / 15 minutes from iginition, this message will be showed “WORK”. This means the appliance is correctly working and the burning is
stable . now you can set both room temperature and thermal output. The fan will automatically start when the heat exchanger temperature will reach
the correct level. When the appliance is in use FIRE POT CLEANING will be displayed after each hour burning and will automatically disappear after
the self clearing procedure being performed..
20. ROOM TEMPERATURE SETTING
Desired room temperature can be set.
When room temperature value being reached the appliance switches in the modulation status and “WORK MODULAT” will be displayed.
To modify
21. POWER SETTING
Desired power level can be set (from 1 to 5). Much higher the selected power level, much quicker the appliance will reach the set room temperature.
To modify
22. WATER TEMPERATURE CONTROL (only for hydro devices)
Allows you to set the desired max water temperature. Once the set temperature has been reached, the appliance will turn on automatically at power
1. When the detected water temperature drops to some degree, the appliance will return to the power previously set. If the water temperature
reaches 90 ° C, the appliance will turn off automatically. The water circulator is factory-set starting at 45 ° C: below this temperature will not start in
order to avoid condensation.
To modify
23. TURNING OFF OF THE DEVICE.
When you turn off the device with the red button 3, shutdown procedures start while maintaining the fan and the smoke extractor turned on until the
minimum temperature of safety (about 20/30 minutes).
Press and hold for
about 3 seconds
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°