1706K21A
Page 2 of 26
Installation of the DR-119
177
504
120
85
40
9
9
4 x ø 5
All dimensions are in millimetres
Powering the display
The power supply must be 88 to 264VAC, 47 to 63 Hz.
The power supply conductor section will be in line with consumption and the ground conductor will be
a minimum section of 1.5m².
The power supply connector for 220VAC has 3 contacts and is situated in the lower part of the unit.
Connect the power wires following the schema below
1
3
2
1- 230V
2- 230V
3- GND
DR-119 characteristics.
Power supply
............................................... 88 to 264VAC, 47 to 63 Hz.
Consumption
................................................ 35VA
Consumption at minimum brightness
....... 13,2VA.
Display
.......................................................... 4 digits 7segments 100mm two central dots. Red LED.
....................................................................... Visibility 50 meters.
Environmental conditions
.......................... Operating temperature: -20 to 60ºC.
....................................................................... Storage temperature: -30ºC to 70ºC
....................................................................... Relative humidity: 5-95% non condensation.
....................................................................... Maximum environmental lighting: 1000 lux.
....................................................................... Protection IP 41 or IP65.
Weight
........................................................... .4,5 Kg.
Timed power-up of the display
This display operates in two operation modes: full-operative mode and power-saving mode. In power-
saving mode the display does not show the time in order to save energy when the display is not needed. If the
power-saving function is not needed and the display should always powered up, the both power-up and
power-down times must be the same.