background image

1660K023G 

 

Page 5 of 30 

Parameter 3: Time offset:

 This parameter allows the user to configure its time zone, as well as changing the 

time offset in summertime/wintertime when configuring it manually, or for personal purposes; always counting 
that  internal  time  count  of  the  clock  is  GMT.  First  digit  shows  an  upper  hyphen  when  adding  time  and  a 
hyphen when subtracting  

Parameter  4:  Display  configuration

:  This  parameter  configures  other  functionalities  of  the  display,  as  the 

brightness and the sync options. 
Brightness configuration consists of two parts: 

Left digit. Manual or automatic control of brightness 

0 - Automatic control of brightness depending on the room light. 
1 - Manual control of brightness. Fixed brightness depending on the right digit. 

 

Right digit. Brightness level. 
The functionality of this digit depends on the left digit: 

Automatic 

mode 

–  Selection  of  the  minimum  brightness  of  the  display  when  the  room  is  in 

darkness. Minimum brightness is 1 and maximum is 5. With light, the display adapts to the amount of 
light in the room. 

Manual mode 

- Selection of the brightness level. 1 is minimum and 5 is maximum brightness 

 

The second parameter (Accessed through the Enter  key once selected the brightness configuration) 

configures  the  time  sync  depending  on  the  capabilities  and  the  user  desires.  If  the  user  selects  a  sync  not 
allowed by capabilities, the display will not sync. For example, a display without Ethernet connection, selecting 
SNTP sync will have no effect. Options are: 

0.  Do not sync. 
1.  Sync with another display through Ethernet. 
2.  Sync through SNTP. 
3.  Sync with another display through RS-485. 
4.  Sync through GPS. 

 

Parameter  5:  Display  power-up  time: 

This parameter configures the time the display changes form power-

.save  mode  to  full-operative  mode.  When  accessing  in  this  parameter,  the  hour  the  display  changes  to  full-
operative  mode  is  shown.    When  the  Enter  key  is  pressed,  the  minutes  are  shown.  To  go  back  to  the 
parameter menu, press the Enter key again. 

Parameter  6:  Display power-down  time: 

This parameter configures the time the display changes from full-

operative  mode  to  power-save  mode.  When  accessing  in  this  parameter,  the  hour  the  display  changes  to 
power-save  mode  is  shown.    When  the  Enter  key  is  pressed,  the  minutes  are  shown.  To  go  back  to  the 
parameter menu, press the Enter key again. 

 

Parameter 7: Website language. This parameter is shown if the display includes Ethernet option. 

0 - Catalan 
1 - Spanish 
2 - English 

– French 

4 - German 
 

Parameter  8:  Display  IP.  This  parameter  is  shown  if  the  display  includes  Ethernet  option. 

This 

parameter  allows  the  user  to  change  the  IP  address  of  the  display.  Access  this  parameter  pressing  the 
Advance  key.  Once  inside,  the  first  number  of  the  IP  address  is  shown.  Modify  it  using  the  Increase  and 

Advance keys and validate it using the Enter key. Do the same with the other 3 numbers of the IP address. To 
identify  each  number,  think  that  the  first  number  is  shown  without  decimal  point.  Next  numbers  appear  with 
decimal points, shifting left each number. 

Summary of Contents for DC-41SRTHO

Page 1: ...er up This is done using one of the parameters of the display see GPS option in this manual If the display includes option NE Ethernet connectivity this display hosts a web site where the user can see the status of the display and configure it This function allows the display to be used as a server for other displays to synchronize the hour through the Ethernet as well as updating its time and dat...

Page 2: ...ove the methacrylate cover Place the 4 supplied plugs at the distance showed in the drawing Place the 2 upper screws leaving their head outside for 4 mm Hang the display using the upper side zig zag Place the lower screws Tighten all the screws Replace the methacrylate cover Powering the display Power supply must be from 100VAC to 240VAC 50 60 Hz You must use a Schuko type plug that has grounded t...

Page 3: ...ppm or 3 of the measurement between 400 and 1250ppm CO2 resolution 1ppm Sensor cable length 2 meters Timed power up of the display This display operates in two operation modes full operative mode and power saving mode In power saving mode the display does not show the time in order to save energy when the display is not needed If the power saving function is not needed and the display should alway...

Page 4: ...guration easy for the user when changing a parameter a point is turned on This point changes depending on the sub parameter if it exists the user is in 8 8 88 88 88 8 8 88 88 8 8 ENTER ENTER ENTER Parameters are detailed below Parameter 1 Date configuration This parameter configures de date as well as the wintertime summertime automatic switchover configuration When entering this parameter the day...

Page 5: ...ay without Ethernet connection selecting SNTP sync will have no effect Options are 0 Do not sync 1 Sync with another display through Ethernet 2 Sync through SNTP 3 Sync with another display through RS 485 4 Sync through GPS Parameter 5 Display power up time This parameter configures the time the display changes form power save mode to full operative mode When accessing in this parameter the hour t...

Page 6: ...ds 8 bits Odd 1 17 9600 Bauds 8 bits Odd 1 18 19200 Bauds 8 bits Odd 1 19 4800 Bauds 7 bits No parity 2 20 9600 Bauds 7 bits No parity 2 21 19200 Bauds 7 bits No parity 2 22 4800 Bauds 8 bits No parity 2 23 9600 Bauds 8 bits No parity 2 24 19200 Bauds 8 bits No parity 2 25 4800 Bauds 7 bits Even 2 26 9600 Bauds 7 bits Even 2 27 19200 Bauds 7 bits Even 2 28 4800 Bauds 8 bits Even 2 29 9600 Bauds 8 ...

Page 7: ...Displays that include GPS sync with the GPS standard signal This allows a better time sync without Ethernet connectivity GPS antenna includes a magnet that can be fixed to a ferric surface This antenna must be placed close to a window or in a place with thin roof The most hidden the antenna is the longer will take to get the GPS signal GPS can spend up to half an hour to fix the signal if the ante...

Page 8: ... range of you LAN it is recommended to use the PC program Display Discoverer downloadable from the web www lartet com In this program the displays connected to the LAN are displayed as well as their IP addresses their MAC addresses all MAC are 00 04 A3 xx xx xx and its name The default name of the display is its serial number This name can be changed in the Ethernet tab of the web server of the di...

Page 9: ...1660K023G Page 9 of 30 Tip the new IP and click OK There will appear a message in the main window with the message sent to the display ...

Page 10: ...1660K023G Page 10 of 30 After some seconds click the Refresh button The display appears with the new IP Click the display IP to open a new tab in the browser The main page of the web server is shown ...

Page 11: ...a difficult access point The web page can be accessed remotely if the router is correctly redirected See Annex 2 View the web page remotely for more information The main page shows the same date and time of the display as well as the temperature the humidity the CO2 concentration and the GPS signal quality if the option is included and the display IP This main page is for the user to control the s...

Page 12: ...n in the field The second tab allows configuring the network parameters of the display including the IP address DNS etc The display can use DHCP to get these parameters on its own The name of the display can be changed according to the needs of the user This name is used to identify and access the display throw web browser typing the name in the URL In case of failure or errors reset the display b...

Page 13: ...actions parameters seen from the webpage the user must configure Other parameters don t care Networks with one display One display Ethernet network Ethernet network Time and date introduction by user if necessary Configure net parameters Sync no One display with GPS Ethernet network Ethernet network Review parameter A GPS signal Sync GPS Review parameter A from the web ...

Page 14: ... Both are configured the same way Ethernet network Ethernet network Ethernet network Ethernet network SNTP server Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net parameters Sync SNTP Write the server addres in the field ...

Page 15: ...thers sync with the server display Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server display Configure net parameters Sync GPS DHCP no Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field ...

Page 16: ...SNTP server and serves the time to the other displays Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server display Configure net parameters Sync SNTP Write the server addres in the field DHCP no SNTP server Client display Configure net parameters Sync Display Ethernet Write the display server addres in t...

Page 17: ...rver o a cloud SNTP server All displays update from the SNTP server specified Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net parameters Sync SNTP Write the server addres in the field Configure net parameters Sync SNTP Write the server addres in the field ...

Page 18: ...0 The following frames can be sent Command Code Data End of block Display time request P H Display temperature request P T Display humidity request P U Displayed CO2 request P C Time programming F H Display time request Frame This frame only includes the code This does not send any data Code End of block ACII P H Hexa 50h 48h Response frame Code Data End of block Code Day Month Year Space Hour Min...

Page 19: ...CII R T T T T Hexa 52h 54h 2Eh Example Temperature 17 2ºC Code Data End of block ASCII R T 1 7 2 Hexa 52h 54h 31h 37h 2Eh 32h Display humidity request Frame This frame only includes the code This does not send any data Code End of block ACII P U Hexa 50h 54h Response frame Code Data End of block ASCII R U H H Hexa 52h 54h Example Humidity 60 Code Data End of block ASCII R U 6 0 Hexa 52h 54h 36h 30...

Page 20: ... CO2 concentration 728ppm Code Data End of block ASCII R U 0 7 2 8 Hexa 52h 54h 30h 37h 32h 38h Time programming Frame Code Data End of block Code Day Month Year Space Hour Minute Second End of block ASCII F H DD MM AA HH MM SS Hexa 46h 48h 20h Example 13 06 00 16 05 2013 Code Data End of block Code Day Month Year Space Hour Minute Second End of block ASCII F H 16 05 13 13 16 00 Hexa 46h 48h 31h 3...

Page 21: ...tion must be the same for all RS 485 network There are many configurations possible only with RS 485 or combining different options this displays offer The following networks are the most usual but the user can create new ones Sync through one display without more options RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server disp...

Page 22: ...023G Page 22 of 30 Sync through a display with GPS RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Sync Parameter 4 2 4 GPS ...

Page 23: ...ed to a SNTP server Ethernet network Ethernet network RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Server display Configure net parameters Sync SNTP Write the server addres in the field SNTP server Client display Sync Parameter 4 2 3 RS 485 ...

Page 24: ...request P U Display CO2 concentration request P C Time programming F H Display time request Frame This frame only includes the code This does not send any data Code Address End of block ACII P H H L Hexa 50h 48h Example Request time from the display in address 03 Code Address End of block ACII P H 03 Hexa 50h 48h 30h 33h Response frame Code Address Data End of block Code Address Day Month Year Spa...

Page 25: ...54h Example Request temperature from the display in address 03 Code Address End of block ACII P T 03 Hexa 50h 54h 30h 33h Response frame Code Address Data End of block ASCII R T H L T T T Hexa 52h 54h 2Eh Example Response from the frame sent in the example before Temperature 17 2ºC Code Address Data End of block ASCII R T 03 1 7 2 Hexa 52h 54h 30h 33h 31h 37h 2Eh 32h ...

Page 26: ... Hexa 50h 54h Example Request temperature from the display in address 03 Code Address End of block ACII P U 03 Hexa 50h 54h 30h 33h Response frame Code Address Data End of block ASCII R U H L H H Hexa 52h 54h Example Response from the frame sent in the example before Humidity 60 Code Address Data End of block ASCII R U 03 6 0 Hexa 52h 54h 30h 33h 36h 30h ...

Page 27: ...esponse from the frame sent in the example before CO2 concentration 728ppm Code Address Data End of block ASCII R U 03 0 7 2 8 Hexa 52h 54h 30h 33h 30h 37h 32h 38h Time programming Frame Code Address Data End of block Code Address Day Month Year Space Hour Minute Second End of block ASCII F H H L DD MM AA HH MM SS Hexa 46h 48h 20h Example Send 13 16 00 16 05 2013 to the display at address 03 Code ...

Page 28: ...inal Port The same port as the start port Internal Start Port The port the user enters wants to enter the display In this case the port is 80 which is the standard web page access IP address The LAN IP of the display Port redirection configuration Server name External Start Port External Final Port Protocol Internal Start Port Internal Final Port Server IP address Display 10021 10021 TCP 80 80 192...

Page 29: ...lies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagnetic Compatibility Standard UNE EN 61000 6 4 Generic Emission Standard Industrial environment Standard UNE EN 61000 6 2 Generic Immunity Standard Industrial environment Directive 2011 65 CE Restriction of the use of ce...

Reviews: