background image

 

 

 

WALTP-Q500 

Larson Electronics, LLC

 

      Phone: (800) 369-6671 

 

Fax: (903) 498-3364  

www.larsonelectronics.com 

2

 of 

2

 

5. 

To remove the bulb, grip one end of the bulb and gently push towards the other end and pull outward to release the 
bulb. 

6. 

Using a clean cloth or wearing gloves to hold the bulb, gently insert one end of the bulb into the receptacle and press 
firmly into place. Place the other end of the bulb into the opposite receptacle and gently press into place. Make sure 
bulb is seated properly. 

7. 

Close the lens cover and replace the retaining screw. 

8. 

Do not test light without lens cover properly attached. 

REPLACEMENT PARTS 

The WALTP-Q500 is designed to provide years of reliable performance. Should the need for replacement parts arise, 
please see part numbers below and attached drawings in next section.  
Some parts may be sourced locally from your nearby hardware store. 

Description: 

Part Number: 

Replacement Bulb Set: 

WAL-SB-500Q-KIT

 

Replacement Lens: 

WAL-M-183

 

Replacement Quartz Lamp 

WALTP-Q500-RH

 

MAINTENANCE

 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing 

maintenance. 

1. 

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine checks to be 
made on a yearly basis. Frequency of use and environment should determine this.  It is recommended to follow 
an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommended practice for Electrical 
Equipment. 

2. 

The lens should be cleaned periodically as needed to ensure continued photometric performance. Clean the 
lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid cleaner. 

3. 

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or contamination 
(i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed. 

4. 

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 

 

USE AND CARE 

Always check damaged or worn out parts before using the work light. When work light is not in use, store it in a secure place 
out of the reach of children. Inspect for good working condition prior to storage and before re-use. 
 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION 
REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT 
LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

 

 

Reviews: