background image

WAL-QP8-WP60PM-GRC50

 

Cord Reel

PERSONNEL SAFETY 

Personal injury and/or equipment damage may result if proper safety precautions are not observed. 

Ensure that power supply voltage does not exceed maximum voltage rating of reel.

Ensure that reel is properly installed before connecting to power supply.

Ensure that all electrical power is removed from reel before servicing.

A high-tension spring assembly is contained within the reel. Exercise extreme caution.

Check for frayed and/or broken wires before each use.

Pull electrical cord from reel by grasping the electrical cord itself, not the work device.

If an electrical malfunction should occur, remove power from reel immediately.

Ensure that reel, electrical cord, and equipment being serviced are properly grounded Use an
ohmmeter to check ground continuity.

If reel ceases to unwind or rewind, remove power immediately. Do not pull or jerk on electrical
cord.

Treat and respect the reel as any other piece of machinery, observing all common safety
practices.

TROUBLE SHOOTING INSTRUCTIONS 

Troubleshooting of the reel consists of isolating a problem to a defective cord/work device, brushholder, 
brushes, or collector. Refer any other discrepancies only to an authorized service person or directly to 
Larson Electronics. 

WARNING: 

The following procedure directs the technician to take voltage measurements. 

Remember, even low voltage is dangerous and can cause personal injury or death. Exercise 
extreme caution!

 

1. If work device is either an incandescent or fluorescent light, replace bulb with a known good

bulb. If this does not correct the problem, proceed to step 2. If work device is an electrical
receptacle, ensure that tool or fixture connected to it is in good working order.

2. Remove power from reel.
3. Remove access cover.
4. Reapply power to reel.
5. Check for correct voltage at terminal strip. If voltage reading is correct, replace electrical

cord/work device. If voltage reading is incorrect, proceed to step 6.

6. Remove power from reel.
7. Remove brushholder from reel and inspect brushholder and brushes. Replace defective

components. Proceed to step 8.

8. Reapply power to reel.
9. Check for correct voltage at terminal strip. If voltage reading is still incorrect, replace defective

collector.

10. Replace access cover.

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 of 

1

 

Summary of Contents for WAL-QP8-WP60PM-GRC50

Page 1: ... the receptacle will accept the cord cap attached to the light Place the light in the desired location and run its power cord to a power source The light head can be adjusted by loosening the screws on each side positioning the light head and tightening the screws to hold the light in place This light is instant on once plugged in to a live circuit AVOID DIRECT EYE EXPOSURE Do not look at the face...

Page 2: ...of isolating a problem to a defective cord work device brushholder brushes or collector Refer any other discrepancies only to an authorized service person or directly to Larson Electronics WARNING The following procedure directs the technician to take voltage measurements Remember even low voltage is dangerous and can cause personal injury or death Exercise extreme caution 1 If work device is eith...

Page 3: ...on on reel by adding or removing wraps of electrical cord from spool one wrap at a time until desired tension is obtained Add wraps to increase tension Remove wraps to decrease tension WARNING When adding wraps of electrical cord be careful not to exceed the winding mechanism s spring capacity Add just enough wraps of cord to achieve the desired tension Damage to the winding mechanism will result ...

Page 4: ...d height is achieved with at least 1ft 2ft remaining inside pole for support This adjustable and collapsible quadpod can be extended to twelve feet and collapsed to four and a half feet WARNING DO NOT over extend T head completely allowing extension pole to free from base If the T head becomes free serious injury or death can occur Larson Electronics shall not be held liable for injuries caused by...

Page 5: ... a yearly basis Frequency of use and environment should determine this 2 Do not operate if any part of the WAL QP8 WP60PM GRC50 is damaged REPLACEMENT PARTS The WAL QP8 WP60PM GRC50 is designed to provide years of reliable performance Should the need for replacement parts arise please contact manufacturer Some parts may be sourced locally from your nearby hardware store WARRANTY Should further inf...

Reviews: