SYSTEM CONNECTION

1. Connect the battery to the charge regulator - plus and 

minus.

2. Connect the photovoltaic module to the regulator - plus and 

minus.

3. Connect the consumer to the charge regulator - plus and 

minus.

The reverse order applies when uninstalling. An 

improper sequence order can damage the 

controller.

DISPLAY /SETTINGS

main display

float voltage

Browsing

interface

Press

MENU

to

browse

different interface.

battery type

Set parameter

discharge reconnect

In interface2-5,long

press MENU to enter

setting,and using[UP]

[DOWN] to set the

parameter,long press

MENU again to exit.

Long press [DOWN] to

restore parameter.

work mode

discharge stop

1. Press the DOWN button to ON/OFF load manually 

at main display.

2. The Work Mode is working as below: 

24H 

1-23H

0H

Load output 24 Hours.

Load on after sunset and closed 

after setting hours.

Dusk to dawn.

TROUBLESHOOTING

Situation

Probable cause

Solution

Charge icon not on

when sunny

Solar panel opened

or reversed

Reconnect

Load icon off

Mode setting wrong

Set again

Battery low

recharge

Load icon slow flashing

Over load

Reduce load watt

Load icon slow flashing

Short circuit protection

Auto reconnect

Power off

Battery too low/reverse

Check battery/connection

Reviews: