GROUND-FAULT CIRCUIT INTERRUPTER (GFCI)

In the event of a ground fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury. 

Definition of a ground fault:

 

Instead of following its normal safe path, electricity passes through a person's body to reach the ground. For example, a 

defective appliance can cause a ground fault. 
A GFCI receptacle does 

NOT 

protect against circuit overloads, short circuits, or shocks. For example, you can still be 

shocked if you touch bare wires while standing on a non-conducting surface, such as a wood floor. 

NOTE:

 

GFCI's contain a lockout feature that will prevent RESET if: 

• There is no power being supplied to the GFCI.

• The GFCI is miswired due to reversal of the LINE and LOAD leads.

• The GFCI cannot pass its internal test, indicating that it may not be able to provide protection in the event of a ground

fault.

GFCI TEST 

Use an approved GFCI tester or plug an electrical device, such as a lamp into the receptacle on which you are working. 

Turn the lamp or device ON. Then, press the TEST button on the GFCI box and power should immediately be switched 

off. If not, contact an electrician. Press the RESET button to restore power. 

The SLEDB-110V-6C from Larson Electronics is a Class 1 LED Beacon that works on 110/120V AC, offers a choice of 

several colors and is equipped with an aluminum base. The SLEDB-110V-6C is also equipped with a 6 foot long cord that 

is terminated in a choice of 125V general area cord caps.

INSTALLATION

This  unit  comes  pre-assembled with the selected color from  factory. Follow the steps below for installing and 

maintaining the strobe light.

MOUNTING 

Mount beacon to any flat surface utilizing the 

aluminum base predrilled with three holes for standard self 

tapping screws

. Mount in any direction. Run cable and connect to compatible power source following all local, 

state, national NEC codes. 

WIRING 
Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where  weatherproofing  may  be  required.  Universal  voltage  driver  permits  operation  at  1

1

0V

/ 120

V  AC

.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure  each  pair  of  wires  according  to  the  diagram.  Utilize  a  junction  box  or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This  unit  comes  pre-wired  from  factory  with  the  selected  cord  cap.  Take 

precautionary  steps  for  weatherproofing  all  connections  if  installed  in  a 

location  where  water  may  come  in  contact  with  the  unit.  All  outdoor 

installations  and  indoor  installations  near  a  wet  location  require  the  use  of  a 

GFCI  device  for  safety,  according  to  the  National  Electrical  Code®  (NEC). 

Ensure the unit is properly grounded. 