![background image](http://html1.mh-extra.com/html/larson-electronics/sledb-110v-30c-xms/sledb-110v-30c-xms_quick-start-manual_3741143002.webp)
SLEDB-110V-30C-XMS
Larson Electronics, LLC
Phone:
Fax: (903) 498-3364
www.larsonelectronics.com
2
of
2
MOTION SENSOR
When the motion sensor detects movement, the strobe light is turned on. Once the motion has stopped, the
strobe will stop.
Sensitivity
,
Time Delay
and
Lux
can be adjusted with their respective
dip switches
on the
motion sensor.
Open the enclosure containing the motion sensor by removing the 4 screws securing the
cover, and adjust according to your desired settings.
NOTE: Switch in the "up" position is "1". Switch in the "down" position is "0".
MAINTENANCE
If the lens becomes dirty, wipe down with a mild soap and water solution.
It is recommended to occasionally inspect the unit for any defects and to ensure the cable is not frayed and is
gripping tightly in all points of cable contact.
(877) 348-9680
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
OR BY PHONE AT
1-877-348-9680
FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR
WARRANTY
AND
RETURN
INFORMATION.
Reach setting (sensitivity)
:
Reach is the term used to describe the radii of the circular detection zone produced after mounting the sensor light at a height of
2.5m. Switch settings and detection
distance as follows:
Timer Setting:
T
ime can be set
10
s to
30
min.
A
n
y
mo
v
ement detected before this time elapse will re
-
start the timer.
I
t is recommended to select the
shortest time for ad
j
usting the detection zone and for performing the wal
k
test. Switch settings and timer configuration as follows:
L
u
x
Setting:
Switch settings and light sensiti
v
it
y
as follows: