background image

SLEDB-110V-30C-XMS 

Larson Electronics, LLC

 

  Phone: 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

2

 

MOTION SENSOR 

When the motion sensor detects movement, the strobe light is turned on. Once the motion has stopped, the 
strobe will stop. 

Sensitivity

Time Delay

 and 

Lux

 can be adjusted with their respective 

dip switches

 on the 

motion sensor. 

Open the enclosure containing the motion sensor by removing the 4 screws securing the 

cover, and adjust according to your desired settings. 

NOTE: Switch in the "up" position is "1". Switch in the "down" position is "0". 

MAINTENANCE 

If the lens becomes dirty, wipe down with a mild soap and water solution. 

It is recommended to occasionally inspect the unit for any defects and to ensure the cable is not frayed and is 
gripping tightly in all points of cable contact.  

(877) 348-9680

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 

1-877-348-9680

 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Reach setting (sensitivity)

:

Reach  is  the term  used  to describe  the  radii  of  the  circular  detection  zone produced  after  mounting the sensor light at a height of 
2.5m.  Switch  settings  and detection 

distance as follows: 

Timer Setting:
T

ime can be set 

10

s to 

30

min. 

A

n

y

 mo

v

ement detected before this time elapse will re

-

start the timer. 

I

t is recommended to select the 

shortest time for ad

j

usting the detection zone and for performing the wal

k

 test. Switch settings and timer configuration as follows:

L

u

x

 Setting:

Switch settings and light sensiti

v

it

y

 as follows: