background image

Larson Electronics LLC     WWW.

LARSONELECTRONICS

.COM

9419 E US HWY 75, Kemp, TX 75143 - P: 903-498-3363 F: 903-498-3364 E: 

[email protected] 

OPERATION: 

Synchronization (Permanent Mount Only): 

To sync two beacons, configure both lights to display the same Phase 1 pattern. With the power off, 
connect the YELLOW wires from each light together. When the lights are activated, their patterns will be 
synchronized. To configure the two lightheads to alternate their patterns, advance the pattern of either 
beacon to the Phase 2 mode of the current pattern. A maximum of 8 lights may be synchronized. 

Setting the Flash Pattern (Magnetic Base): 

Depress the rocker switch on the lighter plug: 

Less than 1 second for the NEXT pattern

1 to 3 seconds for the PREVIOUS pattern

3 to 5 seconds for the DEFAULT pattern

Greater than 5 seconds to TURN OFF the beacon

Setting the Flash Pattern (Permanent Base): 

Connect Blue wire to the Black wire (chassis ground): 

Less than 1 second for the NEXT pattern

1 to 3 seconds for the PREVIOUS pattern

3 to 5 seconds for the DEFAULT pattern

Greater than 5 seconds to TURN OFF the beacon

MAINTENANCE 

The beacons are completely sealed units designed to be maintenance free. Refer to the guide below for 
help with troubleshooting. Should the unit be diagnosed as malfunctioning, remove unit and replace 
with a new module. 

TROUBLESHOOTING 

Problem 

Probable Cause 

Remedy 

Lighthead does not activate 

a. No power to unit

a. Check wire for loose connection

b. Power input wire reversed

b. Reverse power wires

c. Damaged or shortaged cabling

c. Check cables for damage

d. Defective lighthead

d. Replace lighthead module

Lighthead is constantly ON 

a. Control wire permanently
grounded or shorted to GND

a. Avoid permanent grounding of
control wire

Remote:

Use the remote to turn the light on and off.

 

100' 

Range (Includes 1 Remote per Light for Total of 3).