![background image](http://html1.mh-extra.com/html/larson-electronics/ledp5w-30-tp1-50cr/ledp5w-30-tp1-50cr_quick-start-manual_3874678001.webp)
Larson Electronics LLC www.LarsonElectronics.com [email protected]
9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364
LEDP5W-30-TP1-50CR
IMPORTANT:
Read this manual carefully before installing, operating, or servicing this equipment.
PERSONNEL SAFETY
Personal injury and/or equipment damage may result if proper safety precautions are not observed.
Ensure that power supply voltage does not exceed maximum voltage rating of reel.
Ensure that reel is properly installed before connecting to power supply and that the switch is
off.
Ensure that all electrical power is removed from reel before servicing.
A high-tension spring assembly is contained within the reel. Exercise extreme caution.
Check for frayed and/or broken wires before each use.
Pull electrical cord from reel by grasping the electrical cord itself, not the work device.
If an electrical malfunction should occur, remove power from reel immediately.
Ensure that reel, electrical cord, and equipment being serviced are properly grounded Use an
ohmmeter to check ground continuity.
If reel ceases to unwind or rewind, remove power immediately. Do not pull or jerk on electrical
cord.
Treat and respect the reel as any other piece of machinery, observing all common safety
practices.
WARNING:
The switch must be OFF before connecting to power. Otherwise not doing so may
damage the unit.
WARNING:
The following procedure directs the technician to take voltage measurements.
Remember, even low voltage is dangerous and can cause personal injury or death. Exercise
extreme caution!
1.
If work device is either an incandescent or fluorescent light, replace bulb with a known good
bulb. If this does not correct the problem, proceed to step 2. If work device is an electrical
receptacle, ensure that tool or fixture connected to it is in good working order.
2.
Remove power from reel.
3.
Remove access cover.
4.
Reapply power to reel.
5.
Check for correct voltage at terminal strip. If voltage reading is correct, replace electrical
cord/work device. If voltage reading is incorrect, proceed to step 6.
6.
Remove power from reel.
7.
Remove brushholder from reel and inspect brushholder and brushes. Replace defective
components. Proceed to step 8.
8.
Reapply power to reel.