MOUNTING

The IND-HL-HDB-FUVC-EX-1L-120V-15C has a handle at the back of the unit for portable use. At <5 lbs., the lightweight design allows 

the device to be held directly over the target surface or object with ease.

Lamp Replacement

Warning:

 Do not touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance 

and significantly reduce the lifespan of the lamp unless removed with alcohol. Be sure fixture is disconnected from power source and 
cooled off before servicing.

Replace old bulb with one of the same type and rating. 

Remove the 2 plastic rivets located on either side of the handlamp near the lamp 

tube. This will free the tube from the lamp base and allow you to pull it off and access the bulb. Carefully 

remove

  the old bulb

 

from

 the 

fixture and discard in accordance with any local or national regulations. Insert the new bulb 

into the fixture and secure.

 Place the tube 

back onto the lamp and align the rivet holes between the tube and lamp base, then reinstall the rivets. 

WIRING

This unit is equipped with 15 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for 

easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with 

ground or NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard 

wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with 

no plug.

Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

20V AC, 60Hz.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This unit comes pre-wired from factory with the selected cord cap. Take 

precautionary steps for weatherproofing all connections if installed in a 

location where water may come in contact with the unit. All outdoor 

installations and indoor installations near a wet location require the use of a 

GFCI  device for safety, according to the National  Electrical  Code® (NEC). 

Ensure the unit is properly grounded. 