background image

IND-AHF-CD-UVC-R1-

2

20V-50C

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

2

 of 

3

 

Standard pigtail(flying leads wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially  in outdoor 

areas where  weatherproofing  may  be  required.  Universal  voltage  driver  permits  operation  at 

2

20V

  AC

.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure  each  pair  of  wires  according  to  the  diagram.  Utilize  a  junction  box  or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This  unit  comes  pre-wired  from  factory  with  the  selected  cord  cap.  Take 

precautionary  steps  for  weatherproofing  all  connections  if  installed  in  a 

location  where  water  may  come  in  contact  with  the  unit.  All  outdoor 

installations  and  indoor  installations  near  a  wet  location  require  the  use  of  a 

GFCI  device  for  safety,  according  to  the  National  Electrical  Code®  (NEC). 

Ensure the unit is properly grounded. 

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

IND-AHF-CD-UVC-R1-

2

20V-50C

 is designed to provide years of reliable performance. Should the need for 

replacement parts arise, please contact Larson Electronics. 

THESE  INSTRUCTIONS  MAY  NOT  COVER  ALL  DETAILS  OR  VARIATIONS  OF  THIS  PRODUCT  FOR  YOUR  EQUIPMENT  OR  INSTALLATION  REQUIREMENTS. 

SHOULD  FURTHER  INFORMATION  NOT  COVERED  BY  THESE  INSTRUCTIONS  BE  REQUIRED,  PLEASE  CONTACT  LARSON  ELECTRONICS  BY  EMAIL  AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Reviews: