background image

6.

Click the 

 or 

 button to position the 

>

 marker at either SAVE/EXIT or EXIT, and then click the 

Iris +

 button. 

NOTE

SAVE/EXIT

: Use this option if you want to retain the setting. It can be changed at any time. 

EXIT

new setting is lost. 

Example 2: Change the camera video settings

1. 

Open the OSD Main Menu (see “Step 3. Open the OSD menu” on page 2). 

2.

Click the 

 button to position the 

>

 marker at EFFECT, and then click the 

Iris +

 button to open the 

EFFECT submenu. 

3. 

Click the 

 or 

 button to position the 

>

 marker at the parameter you want to change, and then 

click the 

 or 

 button to decrease or increase the setting. The FLIP and RETURN options are 

4. 

Repeat the previous step to change other parameter values if necessary. 

5. 

Click the 

 button to position the 

>

 marker at RETURN, and then click the 

Iris +

 button to return 

to the previous menu (MAIN MENU). 

6.

Click the 

 button to position the 

>

 marker at EXIT, and then click the 

Iris +

 button to open the 

EXIT submenu. 

7. 

Click the 

 or 

 button to position the 

>

 marker at either SAVE/EXIT or EXIT, and then click the 

Iris +

 button.

Cleaning

Clean the camera dome with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time. 

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

Model

IDCMR-ALG-OZ-IC-1080P

Camera

Image Sensor 

1 / 2.7" Progressive Scan CMOS

Signal System

NTSC

1930(H) * 1088(V)

Min. Illumination 

0.1 lux @ (F1.2, AGC ON), 0 lux with IR

Shutter speed 

1/30 s to 1/50,000 s

Lens

3.6 mm lens, angle of View: 90° 

Lens Mount 

M12

Day & Night

ICR

Synchronization

Internal synchronization

Video Frame Rate 

1080p @ 30 fps

HD Video Output 

1 Analog HD output

S / N Ratio 

More than 52 dB

Menu

Camera ID 

AGC 

Support

D/N Mode 

Color / BW/ Auto / EXT

White Balance 

Auto / User / Push / 8000 K / 6000 K / 4200 K / 3000 K

Privacy Mask 

Motion Detection 

BLC 

Support

Language 

English / Chinese

Function

Digital noise reduction, Mirror

General

Working Temperature / Humidity

14 °F ~ 122 °F (-10 °C ~ 50 °C)

Humidity 

90% or less (non-condensing)

Power Supply 

12 Vdc

Power Consumption 

Max. 3W

Weather Proof Ratings 

IP66

IR Range 

Up to 65 ft (20 m)

Communication 

Up the coax (OSD control through the HD-TVI DVR)

Protocol: 

Coaxitron

Dimensions 

Φ2.76” × 5.89” (Φ70 × 149.5 mm) 

Weight 

0.79 lbs (360 g)

Troubleshooting

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 
- Check the video signal cable connection to the monitor. 

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.
- Adjust the monitor controls, if necessary. 
- If the camera is facing a very strong light, change the camera position.
- Adjust the lens focus.

The screen is dark.

- Adjust the contrast control of the monitor.
- If you have an intermediate device, set the impedance (75 Ω /Hi-Z) 

properly, and check the cable connections.

The camera is not working properly and the 
surface of the camera is hot.

- Verify that the camera is correctly connected to an appropriate regulated 

power source.

   If necessary,change the camera position.