BALLAST MAINTENANCE:
Although no routine maintenance is required to keep the
backup micro inverter functional, it should be checked
periodically to ensure that it is working. The following
schedule is recommended:
1.
Visually inspect the charging indicator light monthly.
It should be illuminated.
2.
Test the emergency operation of the fixture at 30-
day intervals for a minimum of 30 seconds. The
lamp should operate at full illumination.
3.
Conduct a 90-minute discharge test once a year.
The lamp should operate at full illumination for at
least 90 minutes.
Refer any servicing indicated by these checks to
qualified personnel!
BATTERY REPLACEMENT:
In order to replace ballast battery, power to fixture must
first be disconnected. It is advised to dismount the fixture
and proceed on a workbench.
Use caution when replacing battery.
1.
Remove the 22 bolts surrounding the ballast box to
free the top cover.
2.
You will also need to dismount the bug eye and exit
lamps. 2 screws hold each to the back plate.
3.
Once free, lift the entire assembly off to reveal the
internal ballast box wiring. You will see the battery
connected to the ballast.
4.
Remove and disconnect the battery. It is connected
via quick connector.
5.
Replace with new battery matching specs.
6.
Once new battery is installed and working, replace
the top cover and light assembly.
7.
Replace the 22 screws for the ballast box cover and
the 2 screws for each lamp.
8.
Make sure all screws have been replaced and return
fixture to installed area.
9.
Energize to resume normal operation.
Dispose of the battery properly. Do not incinerate.
CLEANING:
WARNING:
DO NOT use any solvent or cleanser that
contains alcohol, hydrocarbons, or has potential to
cause an explosion. Using this type of cleanser could
cause an explosion or serious personal injury.
CAUTION:
Clean external parts of light only; internal
parts do not require cleaning. Applying solvent could
result in damage to the electrical equipment.
The HAL-EMG-EXT-12W-2L can be cleaned by applying
Simple Green® or an equivalent cleanser and wiping
any dust or grease off with a rag. After cleaning process
is performed, allow adequate time for light to completely
dry before placing in operation.
WARNING:
When performing maintenance operations
disconnect power. Failure to do so could result in
electrical shock.
USAGE INSPECTION:
Prior to use make a thorough
visual inspection of the light for any chips, cracks, or
burns within the glass, and enclosure. If there are any
cracks in the glass or disturbances in the aluminum
outside of normal wear, remove the light from service
immediately and contact Larson Electronics.
Should further information not covered by these
instructions be required, please contact Larson
Electronics at 1-800-369-6671 or
[email protected] for further assistance.
Please visit LarsonElectronics.com for Warranty and
Return information.