background image

 

 

 

HAL-EMG-EXT-12W-2L 

Larson Electronics, LLC

 

      Phone: (800) 369-6671 

 

Fax: (903) 498-3364  

www.larsonelectronics.com 

2

 of 

2

 

BALLAST MAINTENANCE: 

Although no routine maintenance is required to keep the 
backup micro inverter functional, it should be checked 
periodically to ensure that it is working. The following 
schedule is recommended: 
 

1. 

Visually inspect the charging indicator light monthly. 
It should be illuminated. 

2. 

Test the emergency operation of the fixture at 30-
day intervals for a minimum of 30 seconds. The 
lamp should operate at full illumination. 

3. 

Conduct a 90-minute discharge test once a year. 
The lamp should operate at full illumination for at 
least 90 minutes. 

Refer any servicing indicated by these checks to 
qualified personnel! 
 

BATTERY REPLACEMENT: 

In order to replace ballast battery, power to fixture must 
first be disconnected. It is advised to dismount the fixture 
and proceed on a workbench. 
 
Use caution when replacing battery. 
 

1. 

Remove the 22 bolts surrounding the ballast box to 
free the top cover. 

2. 

You will also need to dismount the bug eye and exit 
lamps. 2 screws hold each to the back plate. 

3. 

Once free, lift the entire assembly off to reveal the 
internal ballast box wiring. You will see the battery 
connected to the ballast. 

4. 

Remove and disconnect the battery. It is connected 
via quick connector. 

5. 

Replace with new battery matching specs.  

6. 

Once new battery is installed and working, replace 
the top cover and light assembly. 

7. 

Replace the 22 screws for the ballast box cover and 
the 2 screws for each lamp.  

8. 

Make sure all screws have been replaced and return 
fixture to installed area. 

9. 

Energize to resume normal operation. 

 
Dispose of the battery properly. Do not incinerate. 
 

CLEANING: 
WARNING:

 DO NOT use any solvent or cleanser that 

contains alcohol, hydrocarbons, or has potential to 
cause an explosion. Using this type of cleanser could 
cause an explosion or serious personal injury. 
 

CAUTION:

 Clean external parts of light only; internal 

parts do not require cleaning. Applying solvent could 
result in damage to the electrical equipment. 
 
The HAL-EMG-EXT-12W-2L can be cleaned by applying 
Simple Green® or an equivalent cleanser and wiping 
any dust or grease off with a rag. After cleaning process 

is performed, allow adequate time for light to completely 
dry before placing in operation. 
 

WARNING: 

When performing maintenance operations 

disconnect power. Failure to do so could result in 
electrical shock. 
 

USAGE INSPECTION:

 Prior to use make a thorough 

visual inspection of the light for any chips, cracks, or 
burns within the glass, and enclosure. If there are any 
cracks in the glass or disturbances in the aluminum 
outside of normal wear, remove the light from service 
immediately and contact Larson Electronics. 
 
Should further information not covered by these 
instructions be required, please contact Larson 
Electronics at 1-800-369-6671 or 
[email protected] for further assistance. 
 
Please visit LarsonElectronics.com for Warranty and 
Return information.

 

 