background image

GAU-KFA-PH-600K-TST

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 of 

16

 

Cart Mounted Forced Air Heater

120V - Kerosene/Diesel - 3000 CFM, 600000 BTUs - 40 Gal Tank - Blue

Instruction Manual

Thank you for your purchase of the Larson Electronics

 GAU-KFA-PH-600K-TST

.

WARNING: 

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

CRITICAL SAFETY INSTRUCTIONS: 

INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY

RELEVANT LOCAL BUILDING CODES.

RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF 

FIXTURE'S

 ELECTRICAL

SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE

 FIXTURE'S

 RATED VOLTAGE.

TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP

OBJECTS. SUITABLE FOR DAMP LOCATIONS.

IMPORTANT

 

READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE.  THE 

GAU-KFA-PH-600K-TST

  MUST  BE  WIRED  IN  ACCORDANCE  WITH  NATIONAL  ELECTRICAL 

CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.  

WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS 

PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT  OF THIS INSTRUCTION SHEET, 

CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE. 

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

RISK OF FIRE/ELECTRIC SHOCK –

 

DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.

 

RISK OF PERSONAL INJURY –

 

FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY. 

RISK OF BURN –

 

ALLOW FIXTURE TO COOL BEFORE SERVICING. 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.

  THIS  LINE

CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT 

READILY AVAILABLE.

 

IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, 

THE CORD MUST BE REPLACED BEFORE RESUMING USE.   

ADANGER 

GENERAL  HAZARD  WARNING: 

Be  sure  to  comply  with  the 

instructions  and  warnings  provided  with  this  heater,  or  death, 

serious bodily 

injury 

and property loss, damage from the hazards 

of fire,  explosion, burn

,

asphyx

i

ation

and ca

r

bon monoxide poisoning can result. 

Only persons  who  can follow and understand these instructions should use or service this 

heater.  If  you  need  heater  information  such  as  an  instruction  manual,  labels,  etcetera, 

contact the  manufacturer. 

ADANGER 

Not for use in residential living areas or in non-adequately ventilated

enclosed spaces.  For outdoor use.  Indoor use permitted for:  The 

temporary heating of adequately ventilated buildiogs or structures 

under construction,  alteration or repair. 

Summary of Contents for GAU-KFA-PH-600K-TST

Page 1: ...CTION SHEET CONSULT AN ELECTRICIAN THERE ARE NO SERVICEABLE PARTS INSIDE WARNING MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE INSTALLATION OR PERFORMING ANY MAINTENANCE RISK OF FIRE ELECTRIC SHOCK DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING RISK OF PERSONAL INJURY FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY RISK OF BURN ALLOW FIXTURE TO COOL BEFORE SERVICIN...

Page 2: ...is mounted on a cart with two wheels and front rear handles for portability and seamless transportation around the work site Warning Check product label for correct input voltage Attach supply line wires to the appropriate light fixture wires as shown in the diagram Secure each pair of wires according to the diagram Utilize a junction box or similar device and take precautionary steps for weatherp...

Page 3: ...ired forced air heater Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 combustion efficiency but does produce small amounts of carbon monoxide Carbon monoxide is toxic ADANGER CARBON MONOXIDE ...

Page 4: ...l storage should be in accordance with federal state or local authorities having jurisdiction Never use this heater in living or sleeping areas NEVER use this heater where flammable vapors may be present I AWARNINGI Risk of electric shock Use only the electrical power voltage and frequency specified on the model plate of the heater Use only a three prong grounded outlet and extension cord ALWAYS i...

Page 5: ...quired to assemble your heater NOTE Save the box and packaging materials for future storage Assembly Front Handle Handle Frame Wheel Support Frame__ Flat Washer L Cotter Pin Flat Washer S Figure 2 Assembly of Model GAU KFA PH 600K TST Fan Guard Wheel Tube Valve GAU KFA PH 600K TST Larson Electronics LLC Phone 800 369 6671 Fax 903 498 3364 www larsonelectronics com 5 of 16 ...

Page 6: ...le NOTE When installing wheels tube valve should face out from support frame Figure 2 2 Place flat washers L and cotter pins on axle ends and bend cotter pins with long nose pliers to secure 3 Place wheel cap on flat washers L and put wheel cap in flat washers L end 4 Place heater on wheel support frame Make sure air inlet end rear of heater is over wheels Align the holes on fuel tank flange Inser...

Page 7: ...h a Temperature Limit Control designed to turn the heater off should the internal temperature rise to an unsafe level If this device activates and turns your heater off it may require service Once the temperature falls below the reset temperature you will be ale to start your heater Electrical System Protection This heater s electrical system is protected by a fuse that protects it and other elect...

Page 8: ...oling cycle The cooling cycle cools the combustion chamber Damage to heater can occur if combustion chamber is not cooled Do not restart heater until cc Oling cycle is complete 1 Push OPERATION BUTTON see Figure 5 This will cause heater flame to go out The motor will continue to run during the cooling cycle This allows the fan to cool the combustion cham ber When the cooling cycle approx 2 minutes...

Page 9: ...move it all IMPORTANT Do not store kerosene over summer for use during next heating season Using old fuel may damage heater 3 Reinstall drain bolt as follows i Insert bolt s seal head fully into drain hole so that flange is flush to tank s bottom See Figure 6 ii Insert seal cap fully into head hole so that cap flange is flush to head flange See Figure 6 Drain Bolt Bottom Fron of Fuel Tank Figure 6...

Page 10: ...e B from burner assembly by using wrench 3 Remove burner head from burner assembly 4 Remove lead wire from spark plug 5 Remove spark plug from burner head 6 Carefully remove nozzle from burner head using socket wrench 7 Blow compressed air through face of nozzle this will remove any dirt 8 Inspect nozzle for damage If damaged or clogged replace nozzle 9 Make sure plug is in place on burner head 10...

Page 11: ...fuel filter in clean kerosene 5 Replace fuel filter and fuel cover Fuel filter A on fuel cap 1 Remove fuel cap See Figure 11 2 Take out fuel filter with clean kerosene 3 Wash fuel filter with clean kerosene 4 Replace fuel filter on fuel tank 5 Replace fuel cap on fuel tank fi1 fi1 Figure 10 Removing Fuel Filter Fuel Cap 9 Fuel Gas et Q Fuel Filter A tt1 Figure 11 Fuel Filter A PUMP PRESSURE ADJUST...

Page 12: ...ting conditions NOTE If heater does not ignite when heater is turned on please turn AIR VENT SCREW counter clockwise to release air then turn OPERATION SWITCH back on Wiring Diagram BLACK AC 120V 60Hz EARTH CONTROLLER ASSEMBLY BG ROOM TEMP SETTING TEMP c a c a c a POWER OPERATION CHECK UP m J Jl TEW UP CN1 CN1 WHITE FUSE 10A 250VAC Figure 12 Pump Pressure Adjustment BLACK BLACK GRAY PHOTOCELL GRAY...

Page 13: ...Exploded View 6 4 GAU KFA PH 600K TST Larson Electronics LLC Phone 800 369 6671 Fax 903 498 3364 www larsonelectronics com 13 of 16 ...

Page 14: ...el Photocell Nozzle Fan Motor Assembly Parts List 70 027 0800 70 006 0200 70 041 0110 70 016 0150 70 015 0750 70 021 0800 GAU KFA PH 600K TST Larson Electronics LLC Phone 800 369 6671 Fax 903 498 3364 www larsonelectronics com 14 of 16 GAU KFA PH 600K TST ...

Page 15: ...ump pressure 2 Adjust pump pressure see page 10 Corroded spark plug or incorrect 3 Clean replace spark plug see plug gap page 9 Dirty fuel filter 4 Clean replace fuelfilter seepage 10 Dirty nozzle 5 Clean replace nozzle seepage 9 Moisture in fuel tank 6 Rinse fuel tank with clean fresh Improper electrical conne tion kerosene see page 8 7 Inspect all electrical connections between transformer and c...

Page 16: ...excessive dust build up Clean with a non abrasive cloth if needed 4 Do not operate if the unit is cracked or damaged All fasteners should be properly seated USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn out parts before using the device Store it in a secure place out of the rea...

Reviews: