Step 1.  Before installing the camera ...

The EXPCMR-IP-POE-DPTZ camera can be installed on a ceiling, wall or table.

1. 

Check the package contents and make sure that the device in the package is in good condition and 
all the assembly parts are included. 

2.

Make sure the mounting surface and fasteners are strong enough to withstand at least three times 
the weight of the camera assembly and the mounting bracket (if used). For concrete or cement 
block walls, use an expansion screw to secure the camera or mounting bracket. 

3. 

if possible.

4. 

5. 

damage.

6. 

7. 

clean soft cloth and isopropyl alcohol.  

EXPCMR-IP-POE-DPTZ 6MP 360

°

 PTZ

 

IP Camera Quick Installation Guide

The camera features: 

This document guides you through the basic steps to install and configure the EXPCMR-IP-POE-DPTZ cameras.

• 

1/1.8” progressive scan CMOS

• 

6 mega-pixel image sensor

• 

Up to 3072 x 2048 resolution, 30 fps
360° fisheye panoramic view

• 

• 

Multiple viewing modes

• 

Internal MicroSD card slot for storage up to 64 GB (card not provided)

• 

Virtual PTZ mode 

• 

50 ft IR range

• 

Built-in microphone and speaker

For more information about the software features of this camera, please refer to the 

Camera 

Software User Manual

 

www.larsonelectronics.com

Audio

LINE IN

Alarm

IN/OUT

12 Vdc

Power

RJ-45 LAN

connector

Fisheye Lens

RS-485

connector

Audio

OUT

Cover Removal

Cover Replacement

To lamp or relamp, the cover must be unscrewed. In most cases, a rectangular steel bar about 0.75 
inch (19 mm) x 0.50 inch (13 mm) x about 30.00 inch (762 mm), can be placed between the lugs 
provided on the face of the cover and rotated counter clockwise to accomplish the removal. See Figure 
3. Excessive force must not be used as the bar may slip and cause injury.

Handle lamps with care when removing and replacing. The lamps are vacuum jacketed and may 
implode if broken. Wear safety glasses and gloves when removing and replacing a lamp.

When relamping, clean the reflector and cover glass to maintain efficiency. The glass may be cleaned 
with any non-abrasive conventional glass cleaner. The reflector should be cleaned with a soft cloth 
and soapy water.

Before replacing the cover, thoroughly clean the threads in both the cover and shell (Item 1 in repair 

How to Setup Multiple Views (video)

https://youtu.be/r1H3Mi_eTp8

parts illustration), then lubricate these threads liberally with a non-drying grease or petrolatum. This 
will enable the cover to be turned more easily and will facilitate its removal later for relamping.

Thread the cover onto the shell by hand until the cover contacts the shell o-ring. Use the rectangular 
steel bar to rotate the cover another 1/12 to 1/10 of a turn or between 2.50 inches (64 mm) and 3.00 
inches (76 mm) measured on the outside diameter.

Cover Glass Replacement

If the cover glass (Item 13 in repair parts illustration on page 5) is to be replaced, first loosen the 
retaining ring (Item 12) by turning it counterclockwise with a hammer and drift punch applied to the 
lugs on the ring. Once loose, it may be rotated out by hand. Remove the cover glass and cover o-ring 
(Item 16) which should also be replaced.

Threads in the cover, the retaining ring and the shell should be thoroughly cleaned and then lubricated 
liberally with a non-drying grease or petrolatum to facilitate assembly and disassembly and to inhibit 
corrosion. After replacement of the cover, o-ring and the cover glass, the retaining ring must be 
tightened against the glass with the hammer and the drift punch until the clearance between the 
cover glass and the cover is such that a 0.0015 inch (0.04 mm) feeler will not enter the joint more 
than 1/8 inch (3 mm) at any point.

Figure 3

loosen

loosen

Summary of Contents for EXPCMR-IP-POE-DPTZ

Page 1: ...ps with care when removing and replacing The lamps are vacuum jacketed and may implode if broken Wear safety glasses and gloves when removing and replacing a lamp When relamping clean the reflector an...

Page 2: ...s and Pictures shown here are for a ceiling installation 1 Route extension cables from the camera junction box to the devices it will connect to Do not connect them to these devices at this time The c...

Page 3: ...e User Manual provided with your system or on your vendor s website These Traversing Virtual Plane Detection Intrusion Detection Add access users to the camera Step 4 Install the Discover Tool The Dis...

Page 4: ...is website Add c After clicking Add the IP address will appear in the Websites list Click Close d If a message on the screen requesting that you install a plug in see below click on the message and co...

Page 5: ...16 GB MicroSD card was installed in the camera 1 NOTE If theStatusof the HDD is the HDD is not recognized Check the settings on the NAS menu See the document IP Camera Software User Manual provided on...

Page 6: ...ge Sensor 1 3 CMOS Scanning Mode Progressive Scan Resolution Up to 3072 x 2048 3 0 mega pixel approx Minimum Illumination Color 0 3 Lux F2 8 AGC On B W 0 Lux IR ON Day Night True Day Night ICR Electro...

Page 7: ...nsumption 12 W Max Weight 3 1 lbs Dimensions 1 72 H x 6 46 operating Temperature 22 F 140 F Operating Humidity 0 95 RH Non condensing Ingress Protection IP66 Impact Protection IK10 Color White Materia...

Reviews: