1
EXPCMR-IP-POE-DPTZ
Step 1. Before installing the camera ...
The EXPCMR-IP-POE-DPTZ camera can be installed on a ceiling, wall or table.
1.
Check the package contents and make sure that the device in the package is in good condition and
all the assembly parts are included.
2.
Make sure the mounting surface and fasteners are strong enough to withstand at least three times
the weight of the camera assembly and the mounting bracket (if used). For concrete or cement
block walls, use an expansion screw to secure the camera or mounting bracket.
3.
if possible.
4.
5.
damage.
6.
7.
clean soft cloth and isopropyl alcohol.
EXPCMR-IP-POE-DPTZ 6MP 360
°
PTZ
IP Camera Quick Installation Guide
The camera features:
This document guides you through the basic steps to install and configure the EXPCMR-IP-POE-DPTZ cameras.
•
1/1.8” progressive scan CMOS
•
6 mega-pixel image sensor
•
Up to 3072 x 2048 resolution, 30 fps
360° fisheye panoramic view
•
•
Multiple viewing modes
•
Internal MicroSD card slot for storage up to 64 GB (card not provided)
•
Virtual PTZ mode
•
50 ft IR range
•
Built-in microphone and speaker
For more information about the software features of this camera, please refer to the
Camera
Software User Manual
.
www.larsonelectronics.com
Audio
LINE IN
Alarm
IN/OUT
12 Vdc
Power
RJ-45 LAN
connector
Fisheye Lens
RS-485
connector
Audio
OUT
Cover Removal
Cover Replacement
To lamp or relamp, the cover must be unscrewed. In most cases, a rectangular steel bar about 0.75
inch (19 mm) x 0.50 inch (13 mm) x about 30.00 inch (762 mm), can be placed between the lugs
provided on the face of the cover and rotated counter clockwise to accomplish the removal. See Figure
3. Excessive force must not be used as the bar may slip and cause injury.
Handle lamps with care when removing and replacing. The lamps are vacuum jacketed and may
implode if broken. Wear safety glasses and gloves when removing and replacing a lamp.
When relamping, clean the reflector and cover glass to maintain efficiency. The glass may be cleaned
with any non-abrasive conventional glass cleaner. The reflector should be cleaned with a soft cloth
and soapy water.
Before replacing the cover, thoroughly clean the threads in both the cover and shell (Item 1 in repair
How to Setup Multiple Views (video)
https://youtu.be/r1H3Mi_eTp8
parts illustration), then lubricate these threads liberally with a non-drying grease or petrolatum. This
will enable the cover to be turned more easily and will facilitate its removal later for relamping.
Thread the cover onto the shell by hand until the cover contacts the shell o-ring. Use the rectangular
steel bar to rotate the cover another 1/12 to 1/10 of a turn or between 2.50 inches (64 mm) and 3.00
inches (76 mm) measured on the outside diameter.
Cover Glass Replacement
If the cover glass (Item 13 in repair parts illustration on page 5) is to be replaced, first loosen the
retaining ring (Item 12) by turning it counterclockwise with a hammer and drift punch applied to the
lugs on the ring. Once loose, it may be rotated out by hand. Remove the cover glass and cover o-ring
(Item 16) which should also be replaced.
Threads in the cover, the retaining ring and the shell should be thoroughly cleaned and then lubricated
liberally with a non-drying grease or petrolatum to facilitate assembly and disassembly and to inhibit
corrosion. After replacement of the cover, o-ring and the cover glass, the retaining ring must be
tightened against the glass with the hammer and the drift punch until the clearance between the
cover glass and the cover is such that a 0.0015 inch (0.04 mm) feeler will not enter the joint more
than 1/8 inch (3 mm) at any point.
Figure 3
loosen
loosen