6
EXP-MS-30W-N4X
Mounting height:
16 ft
5
4
COM
NO
NC
12-24 V
AC-DC
RED
BLACK
WHITE
GREEN
YELLOW
3
Connect the wires to the
door controller. Choose
between NO and NC
contact.
Tighten Screw
(both sides)
Maximum angle ( +30
°
above horizon)
Tighten Screw
(both sides)
Minimum angle ( -90
°
below horizon)
1.
Bolt the bracket securely to the wall or other rigid surface.
2.
Make sure that the two 5/16 - 18 Allen head bolts are loose so that the sensor can rotate freely.
3.
Rotate the sensor to the appropriate angle for the application. When the bracket rotates, it will click. Every click
represents a 7 1/2 angle adjustment.
4.
Lock the angle adjustment by tightening the two 5/16 - 18 Allen head bolts.
5.
Horizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the
desired angle.
NOTE: Normally, opening the sensor is not
necessary, unless access to the manual
pushbuttons is required.
• Using a hex key loosen or tighten the setscrew located
on the side of the housing.
• Unscrew/ Screw the housing cover.
Set screw
EXP-MS-30W-N4X | Larson Electronics, LLC
Page
2
of
4
INSTALLATION TIPS
-
The sensor must be firmly fastened in order not to vibrate.
-
The sensor must not be placed directly behind a panel or any kind of material.
-
The sensor must not have any object likely to move or vibrate in its sensing field.
-
The sensor must not have any fluorescent lighting in its sensing field.
WIRING/ HOUSING OPENING AND CLOSING
MOUNTING ADJUSTMENT
DETECTION FIELD DIMENSIONS