Certifications - Compliance

-

Class I, Divisions 1 & 2, Groups B, C, D

-

Class I, Zones 1 & 2, Groups IIB+H2, IIA

-

Class II, Divisions 1&2, Groups E,F,G

-

Class III, Divisions 1&2

-

Ex db IIC Gb

-

Ex tb IIC Gb Db IP66

-

NEMA 3,4,4X,7 (B,C,D), 9 (E,F,G)

Malfunction

Cause

Remedy

The load will not work

- wrong light control setting selected

- load faulty

- mains switch OFF

- adjust setting

- change load

- switch ON

The load is always working

- continuous movement in the

detection zone

- check zone setting

Load works without and identifiable 

movement

- sensor is not mounted for detecting

movement reliably

- movement occurred, but not

identified by the sensor (movement

behind a wall, movement of small

object in immediate vicinity etc.)

- securely mount enclosure

- check zone setting

The load will not work despite 

movement

-rapid movements are being

suppressed to minimize

malfunctioning or the detection zone

you have set is too small

-check zone setting