WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION 

CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE 

MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED 

PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL. 

PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY 

ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.  

ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE. 

INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT 

ELECTRICIAN. 

IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR 

DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE 

CONTINUING SERVICE. 

Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle 

within the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical  connection  between  plug  and  compatible  receptacle  is  accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift  receptacle  door  and  locate  polarization  on  mating  plug  pin  and

receptacle  face.  Insert  plug  straight  all  the  way  into  receptacle  until  it

cannot go further.

2.

Rotate  plug  clockwise  limit  (37º),  this  closes  internal  contacts  and

completes  circuit.  This  also  mechanically  locks  plug  into  receptacle  so  it

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

straight out.

The EPLC2-MB-100LED-100 Magnetic Mount Explosion Proof LED Light from Larson Electronics is rated Class 1 Division 

2 Groups C & D and Class 2 Division 1-2 and uses a low profile LED light head to produce 14,000 lumens of light while 

drawing only 100 watts.

Magnetic Warning 

PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE.

ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO HEART PACEMAKER COULD CAUSE

PACEMAKER INTERFERENCE OR PACEMAKER FAILURE.

KEEP FINGERS AWAY FROM MAGNET WHEN MOUNTING AS INJURY COULD OCCUR.

This explosion proof light is designed for illumination of industrial locations. It uses the latest in solid state lighting technology for 
long life, low maintenance and high efficiency. 

The unique design focuses the light where it is needed, giving improved efficiency over a conventional HID luminaire. 

An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any nominal 1

2

0-277V AC

 

supply without any variation in light output. 

Low voltage and high voltage specific models available as options upon request. 

WARNING 

To avoid the risk of fire, explosion or electric shock, this product should be installed, inspected and maintained by a qualified 
electrician only, in accordance with all applicable electrical codes. 

Summary of Contents for EPLC2-MB-100LED-100

Page 1: ...OR SAFETY WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL OPERATE AND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THERE ARE NO SERVICEABLE PARTS INSIDE WARNING MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE INSTALLATION OR PERFORMING ANY MAINTENANCE RISK OF FIRE ELECTRIC SHOCK DISCONNECT POWER AT BREAKER...

Page 2: ... polarization on mating plug pin and receptacle face Insert plug straight all the way into receptacle until it cannot go further 2 Rotate plug clockwise limit 37º this closes internal contacts and completes circuit This also mechanically locks plug into receptacle so it cannot be pulled out 3 To remove plug push plug inward and turn to counterclockwise pull plug straight out The EPLC2 MB 100LED 10...

Page 3: ...hen hang the lamp assembly from the bracket WARNING If there is moisture present or chance of it in the conduit system then necessary precautions should be taken by the installer to prevent the moisture from entering through the cable or conduit and entering the fixture Failure to comply with the above could void the warranty WIRING see attached wiring diagram This unit comes equipped with 100 fee...

Page 4: ... condition prior to storage and before re use REPLACEMENT PARTS The EPLC2 MB 100LED 100 is designed to provide years of reliable performance Should the need for replacement parts arise please contact Larson Electronics THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIO...

Reviews: