Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle within 

the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

 

receptacle face. Insert plug straight all the way into receptacle until it

 

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

 

completes circuit. This also mechanically locks plug into receptacle so it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.

Low Voltage DC 

Connect  power  to  power  supply  outputting  low  voltage 

at  24

  Volts  DC.  This 

variable  voltage  allows  greater  versatility  without  affecting  light  output.  Ensure 

deutsch connectors are properly connected (If applicable) 

INSTALLATION 

Unpack enclosure.

Run wire through EYS and cord grips on each end.

Make electrical connections following all state, local, NEC codes and all protocols for the
hazardous area. See labels attached to wiring for both Input and Output leads.

Refer to next page for sealing junctions.

If removing cover, make sure there are no loose or pinched wires when closing cover.

Replace and tighten all screws removed before.

MAINTENANCE 

Electrical  and  mechanical  inspection  of  all  components  must  be  performed  on  a  regularly  scheduled  basic,  determined  by  the 
environment and frequency of use. It is recommended that inspection be performed a minimum of once a year. 

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

EPL-TX-8A-EPO-24V-25-EPP

 is designed to provide years of reliable performance. Should the need for 

replacement parts arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Summary of Contents for EPL-TX-8A-EPO-24V-25-EPP

Page 1: ...VE THESE INSTRUCTIONS FOR FUTURE REFERENCE THE EPL TX 8A EPO 24V 25 EPP MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL OPERATE AND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THE...

Page 2: ... CHECKED FOR CUTS BREAKS OR ANY SEVERE ABRASIONS AND IF ANY ARE FOUND THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT ELECTRICAL POWER SUPPLY MUST BE OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT ELECTRICIAN IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING BROKEN OR SHOW SIGNS OR DAMAGE DI...

Page 3: ... state local NEC codes and all protocols for the hazardous area See labels attached to wiring for both Input and Output leads Refer to next page for sealing junctions If removing cover make sure there are no loose or pinched wires when closing cover Replace and tighten all screws removed before MAINTENANCE Electrical and mechanical inspection of all components must be performed on a regularly sche...

Page 4: ...he up position Both access plugs are removed after conductors are installed Damming fiber is installed through the large access port into both ends of the seal fitting body to allow sealing compound to flow to the required thickness Table A Care must be taken to insure the fiber fills all voids around each conductor as well as between conductors and the wall of the seal body Replace the small acce...

Reviews: