EPL-TL-1X10W-C-PA-XFSW

 

Explosion Proof Signal Light w/ Audible Alarm

C1D1, C2D1 - Multiple Colors - External Float Switch

Instruction Manual

Thank you for your purchase of the Larson Electronics EPL-TL-1X10W-C-PA-XFSW. 

WARNING 

TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED, 

INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL 

APPLICABLE ELECTRICAL CODES. 

TO AVOID ELECTRIC SHOCK: 

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

PRODUCT MUST BE  CONNECTED TO A WIRING  SYSTEM  WITH AN EQUIPMENT-GROUNDING

CONDUCTOR.

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

The EPL-TL-1X10W-C-PA-XFSW Explosion Proof Signal Light w/ Audible Alarm and External Float Switch from Larson 

Electronics is suitable for monitoring liquid levels inside flammable work sites. The ATEX-rated system provides visual 

notification via an LED strobe lamp and audio notifications via an audible horn. Constructed of 316 stainless steel, the 

external float switch operates magnetically and is capable of withstanding 2,000 psig (138 bar) of pressure.

SIGNAL LIGHT AND HORN INSTALLATION

We recommend only a licensed electrician install this product!

It is strongly suggested to use two licensed electricians to proceed with the 

final mounting of the fixture to avoid any possible personnel injury or damage 

to the fixture. Depending on mounting height and scaffolding, a hydraulic man–

lift or two good quality ladders should be used. This fixture is heavy and must 

be mounted to a surface that can structurally support the load. Secure the unit 

firmly to the surface by lifting the unit into place, and driving appropriate 

mounting hardware through 

all

 pre-drilled mounting holes in the side flanges of 

the back plate. Failing to comply can result in breakage, allowing the fixture to 

fall, which can cause serious injury or death. Run 3/4" conduit to the junction 

box and wire the unit according to the wire diagram included with your unit. 

Unit should be installed and wired in accordance with all applicable NEC and 

local electrical/building codes. Wiring for the signal light and horn are 

accessible via the junction box at the base of the light fixture.

Larson Electronics, LLC

 

Phone: (877) 348-9680

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 of 

4

 

FLOAT SWITCH INFORMATION AND INSTALLATION

Rugged and reliable, the float switch operates automatically to indicate tank level. Perfect for starting or stopping pumps, 

opening or closing valves, or actuate level alarm signals. A unique magnetically actuated switching design gives superior 

performance. There are no bellows, springs, or seals to fail. Instead, the free-swinging float attracts a magnet within the 

solid metal switch body, actuating a snap switch by means of a simple lever arm. Float arm hinge design limits the arm 

angle to prevent vertical hangup.