EPL-QC-16C-2X150LED-RT-X24V-C1D1-12.3-100-EPP

WIRING

/PLUG

 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

2

0V  -  277V AC, 50 or 60Hz 

stepped down to 24V DC

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

This explosion proof portable lighting system is equipped with 100 feet of 12/3 chemical and abrasion resistant SOOW cord 

that is fitted with an explosion proof cord cap for easy connection to explosion proof outlets. There is an additional 5 feet of 

12/3 SOOW cord between the encapsulated transformer and the explosion proof cord cap. Plug options include a 5-15 15 

amp  straight  blade  plug  for  use  with  120V  explosion  proof  outlets,  a  5-20  20  amp  straight  blade  plug  for  use  with  120V 

explosion proof outlets, or a 6-20 20 amp straight blade plug for use with 220-240V explosion proof outlets. These explosion 

proof cord caps are designed to lock into compatible twist lock receptacles by twisting the plug body until an audible click is 

heard, which indicates the plug is securely connected. Once locked into place this plug will not accidentally pull out.

Additional  configurations  include  general  area  cord  caps,  weatherproof  cord  caps,  shore  power  cord  caps,  weatherproof 

NEMA 3R/4 in-line step-down transformers, and explosion proof NEMA 7/9 in-line step-down transformers.

WIRING

/PLUG

 

This explosion proof portable lighting system is equipped with 100 feet of 12/3 chemical and abrasion resistant SOOW cord 

that is fitted with an explosion proof cord cap for easy connection to explosion proof outlets. There is an additional 5 feet of 

12/3 SOOW cord between the encapsulated transformer and the explosion proof cord cap. Plug options include a 5-15 15 

amp  straight  blade  plug  for  use  with  120V  explosion  proof  outlets,  a  5-20  20  amp  straight  blade  plug  for  use  with  120V 

explosion proof outlets, or a 6-20 20 amp straight blade plug for use with 220-240V explosion proof outlets. These explosion 

proof cord caps are designed to lock into compatible twist lock receptacles by twisting the plug body until an audible click is 

heard, which indicates the plug is securely connected. Once locked into place this plug will not accidentally pull out.

Additional  configurations  include  general  area  cord  caps,  weatherproof  cord  caps,  shore  power  cord  caps,  weatherproof 

NEMA 3R/4 in-line step-down transformers, and explosion proof NEMA 7/9 in-line step-down transformers.

Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle within 

the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

 

receptacle face. Insert plug straight all the way into receptacle until it

 

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

 

completes circuit. This also mechanically locks plug into receptacle so it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.

VOLTAGE

The  C1D1  explosion  proof  step-down  transformer  installed  in-line  provides  the  ability  to  automatically  monitor  and  adjust 

input  current  to  maintain  the  correct  LED  voltage  levels  regardless  of  input  levels  across  a  specific  range.  These 

transformers can operate on current ranging from 90 to 305V AC or 127 to 431V DC without any modifications necessary as 

a result. This ability to sense and adjust input current also provides protection against voltage spikes and drops that can 

occur  in  electrical  systems  which  would  otherwise  result  in  burning  up  or  premature  LED  failure  without  it.  The  inline 

transformer  then  steps  down  the  input  voltage  to  24V  DC  to  power  the  explosion  proof  light.  We  also  offer  an  additional 

347-480V high voltage, 125-250V DC, and 0-10V dimmable versions of this explosion proof LED light fixture.

FIELD SERVICEABILITY

This  explosion  proof  LED  light  fixture  is  field  serviceable.  All  major  internal  components  can  be  purchased  from  Larson 

Electronics  and  installed  by  a  licensed  electrician  with  basic  tools.  With  most  explosion  proof  fixtures,  the  fixture  must  be 

returned to the manufacturer for repair work, which presents downtime and long turn around times for repair work. Larson 

Electronics addresses this issue with the Iron X series with field serviceability, allowing operators to perform service work 

without having to return the fixture to the manufacturer in the event of damage or failure.

Summary of Contents for EPL-QC-16C-2X150LED-RT-X24V-C1D1-12.3-100-EPP

Page 1: ...URE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE THE EPL QC 16C 2X150LED RT X24V C1D1 12 3 100 EPP MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL OPERATE AND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET...

Page 2: ...TRAINED AND COMPETENT ELECTRICIAN IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING BROKEN OR SHOW SIGNS OR DAMAGE DISCONTINUE USE IMMEDIATELY REPLACE WITH THE PROPER REPLACEMENT PART S BEFORE CONTINUING SERVICE WARNING USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE IF WIRING OR LAMP REPLACEMENT INSTRUCTIONS ARE NOT FOLLOWED EXACTLY THE HANDLAMP MAY NOT BE SUITAB...

Page 3: ...h 220 240V explosion proof outlets These explosion proof cord caps are designed to lock into compatible twist lock receptacles by twisting the plug body until an audible click is heard which indicates the plug is securely connected Once locked into place this plug will not accidentally pull out Additional configurations include general area cord caps weatherproof cord caps shore power cord caps we...

Page 4: ...from the mounting base To mount a QC Series compatible light fixture operators simply slide the male end mounting section of the light assembly into the female end mounting section on the mounting base then tighten the locking ring to ensure the light assembly has been secured To dismount operators unscrew the locking ring slide the light head assembly forward and the light assembly has been remov...

Page 5: ...g fins on the luminaire to ensure that they are free of any obstructions or contamination i e excessive dust build up Clean with a non abrasive cloth if needed 4 Do not operate if the lens is cracked or damaged All fasteners should be properly seated USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the life of the equipment Always check f...

Reviews: