Before activating unit, inspect to be sure that there are no obstructions or debris on the fan that would interfere 
with the propeller. Check all fasteners for tightness. 

LAMP 

Use single bolt to provide rotation when mounting. Loosen the two set screws on the bracket to adjust vertical 
position as necessary. Lamp is “instant-on” and will illuminate once power is supplied. 

 

RECEPTACLE OPERATION 

Electrical connection between explosion proof receptacles and plug is accomplished after plug fully inserts into 
receptacle and rotated clockwise. 
 

1. 

Lift receptacle door and locate polarization on mating plug pin and receptacle face. Insert plug straight all 
the way into receptacle until it cannot go further. 

2. 

Rotate plug clockwise limit (37º), this closes internal contacts and completes circuit. This also mechanically 
locks plug into receptacle so it cannot be pulled out. 

3. 

To remove plug, push plug inward and turn to counterclockwise, pull plug straight out.

 

 

REMOVE MOTOR DRAIN PLUGS 

  After installing the fan, remove the motor drain plug located at the lowest 

point of the motor. 

  Failure to remove the drain plug may allow condensation to build up 

inside the motor, reducing motor life and will void the warranty. 

  Do not remove drain plugs on the top side of the motor. 

  Drain plug locations and quantity may vary by motor design. 

 

 

TILT ADJUSTMENT 

The fan can tilt up or down by loosening the fasteners on the motor yoke 
bracket. Loosen the center 3/8” bolt and 1/4” bolt to adjust the fan to the 
desired angle and securely tighten all mounting hardware. 

 

CAUTION: Fasteners may loosen over time. It is 
important to check and tighten fasteners frequently. 

 

MAINTENANCE 

WARNING: 

DISCONNECT POWER BEFORE CLEANING OR MAINTAINING YOUR UNIT IN ORDER TO PREVENT 
SERIOUS INJURY OR DEATH.

 

It is recommended that you implement a standard monthly or more frequent preventive maintenance schedule. 
Safety requires a thorough visual examination of the unit for physical damage that might cause a spark or 
result in the ignition of hazardous atmospheres. 

Maintenance includes a careful examination to ensure at least: 
 

A. 

The Cable is not frayed and is gripping tightly in all points of cable contact. 

B. 

The Cable Jacket is completely intact and that no internal conductors or conductor insulation 
is exposed. 