![background image](http://html1.mh-extra.com/html/larson-electronics/epl-120-150-epp/epl-120-150-epp_instruction-manual_3742380003.webp)
EPL-120-150-EPP
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
3
of
4
Exp Cord Cap
Position device near work area for operation. Run cable to nearby power
source. Insert and twist-lock explosion-proof plug into a compatible receptacle within
the hazardous environment. See
plug operation
below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished
after plug fully inserts into receptacle and rotated clockwise.
1.
Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug straight all the way into receptacle until it
cannot go further.
2.
Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also mechanically locks plug into receptacle so it
cannot be pulled out.
3.
To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.
OPERATION
1.
Position light head in desired location using swivel hook.
2.
Run cable, transformer, and plug
OUTSIDE HAZARDOUS AREA
.
3.
Attach power cord from transformer to
Voltage: 120V/277V AC
compatible receptacle.
WARNING:
Check product label for correct voltage! Failure to comply could
result in damage to the fixture which may not be covered by warranty. The bulb itself
runs on low voltage specified upon purchase.
The LED lamp in this hand lamp is “instant-on” and will illuminate once power is supplied.
LAMP REPLACEMENT
1.
Loosen set screw.
⑧
2.
Unscrew Guard/Globe assembly
⑨
from handle assembly.
3.
Replace with matching lamp.
4.
Inspect o-ring seal
⑪
. If worn or damaged, it must be replaced to
insure watertight seal.
5.
Screw globe assembly completely onto lamp base.
6.
Tighten set screw securely to 6 in-lbs.