EPF-SM-30-100-EPP 

Larson Electronics, LLC

 

          Phone: (800) 369-6671   

 Fax: (903) 498-3364  

     www.larsonelectronics.com 

2

 of 

3

 

 
Fans pre-wired with 120V 3-prong power cord: 

  The power source must conform to the electrical requirements of the fan. 

  The power cord has a 3-prong grounded plug that must be plugged into a compatible circuit. 

  Do not alter the plug to remove the grounding prong and never use a two prong adapter. 

  Replace damaged or worn power cords immediately. 

  Where possible, avoid using extension cords. If one must be used, the cord must be UL listed, be the 

proper size (Amp rating), and have 3-prong grounded connections. 

 
Before activating fan, inspect to be sure that there are no obstructions or debris that would interfere with the 
propeller. Check all fasteners for tightness. 

 

RECEPTACLE OPERATION 

The receptacles are dead-front construction. Electrical connection between it and plug is accomplished after 
plug fully inserts into receptacle and rotated clockwise. 
 

1. 

Lift receptacle door and locate polarization on mating plug pin and receptacle face. Insert plug straight all 
the way into receptacle until it cannot go further. 

2. 

Rotate plug clockwise limit (37º), this closes internal contacts and completes circuit. This also mechanically 
locks plug into receptacle so it cannot be pulled out. 

3. 

To remove plug, push plug inward and turn to counterclockwise, pull plug straight out.

 

 

 

TILT ADJUSTMENT 

The fan can tilt up or down by loosening the fasteners on the motor yoke 
bracket. Loosen the center bolt and adjustment bolt to adjust the fan to 
the desired angle and securely tighten all mounting hardware. 

 

CAUTION: Fasteners may loosen over time. It is 
important to check and tighten fasteners frequently. 

 

LUBRICATION 

This motor is equipped with pre-lubricated ball bearings. The original supply of lubricant is kept free of dirt, grit 
or outside contamination by the bearing closures and does not require replenishment for the life of the bearing 
under normal operating conditions. 

 
MAINTENANCE 

WARNING: 

DISCONNECT POWER BEFORE CLEANING OR MAINTAINING YOUR FAN IN ORDER TO 
PREVENT SERIOUS INJURY OR DEATH.

 

It is recommended that you implement a standard monthly or more frequent preventive maintenance schedule. 
Safety requires a thorough visual examination of the unit for physical damage that might cause a spark or 
result in the ignition of hazardous atmospheres. 

Maintenance includes a careful examination to ensure at least: 

1/4" 

3/8" 