background image

Explosion Proof Cable 

G

land

 

CGB-C1D1-MCHL

 

Series

 

Instruction 

Manual

Summary of Contents for CGB-C1D1-MCHL Series

Page 1: ...Explosion Proof Cable Gland CGB C1D1 MCHL Series Instruction Manual ...

Page 2: ... TO PREVENT WIRING DAMAGE OR ABRASION DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP OBJECTS SUITABLE FOR DAMP LOCATIONS WARNING MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE INSTALLATION OR PERFORMING ANY MAINTENANCE RISK OF FIRE ELECTRIC SHOCK DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING RISK OF PERSONAL INJURY FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROP...

Page 3: ...PMENT GROUNDING CONDUCTOR TO AVOID EXPLOSION MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS ATMOSPHERE DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT NAMEPLATE DO NOT OPERATE IF THE LENS CORD SEALS HOUSING RECEPTACLES ETC IS CRACKED OR DAMAGED IF SO DISCONTINUE USE AND CONTACT ...

Page 4: ...ics LLC earth tags have been independently tested to comply with Category B rating specified in IEC 62444 there are no ratings stated in IEC 60079 0 Ratings are shown in the associated table Larson Electronics LLC earth tags slip over the cable gland or accessory entry thread from inside outside the enclosure and must be secured with a locknut if fitted internally 7 Metric entry threads comply wit...

Page 5: ...e used in Class I Div 1 and 2 and Class I Zone 1 and 2 Classified Areas according to 60079 14 installation wiring method restrictions 6 Installation must be according to US NEC wiring method for the types of cables that can be used in Class I Div 1 and 2 and Class I Zone 1 and 2 Classified Areas according to 60079 14 installation wiring method restrictions 7 Prior to commissioning or operation of ...

Page 6: ...s of the cables to the required length 3 After the tape has been applied cut the cable fillers to the edge of the tape Outer Jacket 1 Cable preparation With Inner Jacket Strip back the jacket armor to suit the equipment geometry Cut inner jacket to length Length groove in hexagon to front of outer nut Using the measure guide cut the cable inner jacket and any cable fillers to the required length I...

Page 7: ...Remove electrical tape from cable core tips Separate the cable cores slightly to allow resin to flow between them When insulating grounding conductors are present spread the strands slightly to allow the resin to form a full seal Refer to sealing compound instructions to fill the gland resin tube with the required amount of sealing compound Note For instrumentation cables utilizing shielded cable ...

Page 8: ... LARSONELECTRONICS COM FOR WARRANTY AND RETURN INFORMATION USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn out parts before using the device Store it in a secure place out of the reach of children when not in use Inspect for good working condition prior to storage and before re u...