CORRECT PROCEDURE OF DECOMPRESSION
• Move the switch (
P1
) to the
OFF
(0)
position to stop the
equipment.
• Unlock the safety clamp (
P2
).
• Point the gun (
P3
) at the receptacle (
P4
) used to collect
the product and press the trigger to release the pressure.
When completed, activate the safety catch again.
WARNING
:
If the equipment is still under pressure after perfor-
ming the operations above described because of
the nozzle or the flexible hose clogged, proceed
as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product
and press the trigger to release pressure.
• Loosen very slowly the fitting of connection
from the flexible hose to the gun.
• Clean or replace the flexible hose and the
nozzle.
• Open the discharge valve (
P5
) to release the remaining
pressure.
www.larius.eu