Technical Report Laplace Instruments Ltd January 2010
RF300 Large loop antenna, an analysis of changes to the standards
These changes are due to the amendments to CISPR15 and CISPR16
The latest versions are now …..
CISPR15:2006 + A2:2009 and
CISPR16-1-4:2007 + A1:2008
The key changes related to LLAs are:
1. Sections related to the construction and specification of LLAs are moved from
CISPR15 to CISPR16. Note that in the new CISPR15, the requirements for the
LLA are referred to Section 4.7.1 in the new CISPR16, which does not exist! It
seems that the reference should be to Section 4.6.1. The same error is repeated
in CISPR16 which again refers in Annex C to the non-existent section 4.7.
2. The definition of the calibration data has been re-defined.
Previous
CISPR15
New CISPR16
Notes
Significant changes
Annex B
Annex C
Description, construction and
validation of LAS
Both annexes combined into one.
Annex C
Clause B1
Clause C1
Introduction
Loop antenna named LAS (Loop
Antenna System
Clause B2
Clause C2
Construction of LAS
Additional requirements for cables and
connectors.
Clause C3
Construction of loop
Information previously included with
diagrams now included in text. Note low
R for inner conductor is required.
Clause B3
-----
Positioning of the LAS
Requirement for minimum distance to
nearby objects,…… not included in new
CISPR16
Clause B4
Clause C4
Validation
New definition for validation factor. (see
below).
Figure B1
Figure C1
General view
None
Figure B2
Figure C2
Position of slits
None
Figure C3
Construction of slits
None
Figure C5
Metal box for current probe
None
Figure B3
Figure C4
Example slit construction
None
Figure B4
Figure C8
Validation factor
Converted from dBuA to dB(
Ω
). See
below.
Figure C7
Positions of calibration loop
None
Figure C9
Construction of calibration loop None
Figure C1
Figure C11
Sensitivity vs diameter
None
Figure C2
Figure C10
Conversion factors between loop
current and magnetic field
strength at a distance.
Factors for magnetic field with electric
field added. Factors for distance 30m
removed.
Summary of Contents for RF300 Mk II-A
Page 2: ...Laplace Instruments Ltd Page 2 This Page intentionally blank...
Page 4: ...Laplace Instruments Ltd Page 4 This Page intentionally blank...
Page 22: ...Laplace Instruments Ltd Page 22 This Page intentionally blank...
Page 24: ...Laplace Instruments Ltd Page 24 This Page intentionally blank...
Page 26: ...Laplace Instruments Ltd Page 26 This Page intentionally blank...
Page 28: ...Laplace Instruments Ltd Page 28...
Page 29: ...Laplace Instruments Ltd Page 29 Appendix B Changes to standards CISPR15 and CISPR16 2009...