48
Lapierre Equipment |
FUSION X
2
EVAPORATOR
| USER MANUAL | Version 01 - September 2022
APPENDIX C
OPTIFLAM
TM
combustion controller (optional) (continued)
Illustration 12
Illustration 13
• Setting the operating parameters
To set the operating parameters, proceed as follows
(Illustration 12):
1. Touch the value to be changed on the touch screen
to bring up the number pad,
2. Enter the required value,
3. Press the [ENTER] key.
5.2 Step 2: STARTING THE EVAPORATOR
Proceed as follows to start the evaporator.
First prepare the evaporator with a load of combustion
chamber fuel ready for ignition.
Then go to the AUTOMATIC mode page (Illustration 5
and 13) by pressing the [AUTOMATIC] key at the top
left of the display.
When you are on this page (Illustration 13) and your
combustion chamber fuel load is ready to be lit,
proceed as follows:
1. Light the combustion chamber fuel load.
2. Close the evaporator door.
3. Press the [RUNNING] key in the centre of the display.
4. The OPTIFLAM
TM
then switches on.
Continue the operation as follows:
5. At the start signal, the evaporator runs for 3 minutes.
6. After this time, a combustion chamber fuel reload request is indicated by two warnings:
- the blue light on the touch screen housing flashes,
- and the message “RELOAD” is displayed under the LAPIERRE identifier on the operating display.
7. The cycle described in #6 will then repeat every 5 minutes until the combustion chamber set point
temperature is reached.
- Using a long poker, push the combustion chamber load backwards. Then place a one to two log thick
combustion chamber fuel reload on the entire surface of the firebox. Start by loading the rear and finish
at the front.
8. When the temperature of 1000 °F (540 °C) is reached in the combustion chamber, the OPTIFLAM
TM
switches
to AUTOMATIC mode. The message “OPERATION” will appear under the LAPIERRE ID on the operation
display.
Summary of Contents for FUSION X2
Page 1: ...USER MANUAL September 2022 LAPIERRE EQUIPMENT All rights reserved 2022 FUSION X2 EVAPORATOR...
Page 54: ...52 Lapierre Equipment FUSION X2 EVAPORATOR USER MANUAL Version 01 September 2022 NOTES...
Page 55: ...53 Lapierre Equipment FUSION X2 EVAPORATOR USER MANUAL Version 01 September 2022 NOTES...