4. MANUAL MODE
MANUAL operation mode allows the operator to run the evaporator by controlling the speed of the air fans
directly.
To do so, the operator must switch from the OPERATING SETTINGS display (Illustrations 4 and 9) to the
MANUAL operation display (Illustrations 3 and 10).
• The CHIMNEY and COMBUSTION CHAMBER TEMPERATURES are displayed continuously in the centre of the
display in MANUAL mode (Illustration 10).
4.1 COMBUSTION CHAMBER FUEL RELOADS
To perform a COMBUSTION CHAMBER FUEL RELOAD, proceed as follows (Illustration 10):
1. turn Off the PRIMARY air fan(s) by setting the value to 0%,
2. adjust the SECONDARY air fan speed to 10%,
3. wait 5 seconds,
4. perform the reload,
5. restart the PRIMARY air fan(s) by adjusting the speed to the desired percentage,
- also adjust the SECONDARY air fan speed to the desired percentage.
Illustration 9
Illustration 10
• Press the [Manual] key at the top right of the
OPERATING SETTINGS display (Illustration 9).
• You will then be directed to the MANUAL operating
mode display (Illustration 10).
Adjust the speed of the combustion air fans using the
two sets of keys [ - ] and [ + ] located at the bottom
of the display.