Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified
electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
This product is rated at IP44.
This product is not suitable for location in or near a marine environment.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
1 x MAX 5W LED GU10
IP rating:
44
•
You have correctly identified
the wires.
•
The connections are tight.
•
No loose strands have been
left out of the connection
block.
If not fitting to a plug, then the product must be wired to a IP44 rated terminal block.
Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Wiring - Terminal Block
Check that...
Layout
• Decide on the position of the luminaire. Depending on the location, an approved outdoor rated plug and socket
may be required. Alternatively an approved outdoor rated external terminal block may be used.
• Avoid locating any cables in positions that would cause a hazard. Position cables and connector block away
from areas where they may be at risk from being cut, trapped or damaged.
• Cables that are to be in walls and concealed underground must be protected using suitable conduit or plastic
trunking.
• Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in
very wet or boggy areas.
Wiring - Plug
• The appliance must be connected to a 240 volts AC
supply.
• The appliance can be fitted to a rewireable 3 pin
plug fitted with a 3 amp fuse. Should the fuse
require replacement, it must be replaced with a fuse
rated at 3 amp and approved to BS1362.
• The wires in the mains lead on this appliance are
coloured in accordance with the following code:
Blue – Neutral
Green / Yellow - Earth
Brown – Live
Commissioning
• Fit the bulb as per the details overleaf
• Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in very
wet or boggy areas. Push the spike into the ground.
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
SUPPLY
LIGHT FITTING
E
L
N
GREEN/ YELLOW
Earth
Fuse
3 Amps
Cord Clamp
BLUE
Neutral
BROWN
Live
KNG2048283_ONLINE.indd 2