background image

 

WiPort™ Integration Guide  

 

 

 

Warranty  

Lantronix warrants each Lantronix product to be free from defects in material and 
workmanship for a period of TWO YEARS. During this period, if a customer is unable 
to resolve a product problem with Lantronix Technical Support, a Return Material 
Authorization (RMA) will be issued. Following receipt of a RMA number, the customer 
shall return the product to Lantronix, freight prepaid. Upon verification of warranty, 
Lantronix will -- at its option -- repair or replace the product and return it to the 
customer freight prepaid. If the product is not under warranty, the customer may have 
Lantronix repair the unit on a fee basis or return it. No services are handled at the 
customer's site under this warranty. This warranty is voided if the customer uses the 
product in an unauthorized or improper way, or in an environment for which it was not 
designed. 

Lantronix warrants the media containing its software product to be free from defects 
and warrants that the software will operate substantially according to Lantronix 
specifications for a period of 60 DAYS after the date of shipment. The customer will 
ship defective media to Lantronix. Lantronix will ship the replacement media to the 
customer.  

In no event will Lantronix be responsible to the user in contract, in tort (including 
negligence), strict liability or otherwise for any special, indirect, incidental or 
consequential damage or loss of equipment, plant or power system, cost of capital, 
loss of profits or revenues, cost of replacement power, additional expenses in the use 
of existing software, hardware, equipment or facilities, or claims against the user by 
its employees or customers resulting from the use of the information, 
recommendations, descriptions and safety notations supplied by Lantronix. Lantronix 
liability is limited (at its election) to: 

 

Refund of buyer's purchase price for such affected products (without 
interest). 

 

Repair or replacement of such products, provided that the buyer follows the 
above procedures. 

There are no understandings, agreements, representations or warranties, expressed 
or implied, including warranties of merchantability or fitness for a particular purpose, 
other than those specifically set out above or by any existing contract between the 
parties. Any such contract states the entire obligation of Lantronix. The contents of 
this document shall not become part of or modify any prior or existing agreement, 
commitment or relationship. 

For details on the Lantronix warranty replacement policy, go to our web site at 

www.lantronix.com/support/warranty

 

 

Summary of Contents for WiPort

Page 1: ...WiPort Integration Guide Part Number 900 333 Revision G June 2006...

Page 2: ...trademark of The Open Group Windows 95 Windows 98 Windows 2000 Windows NT and Windows XP are trademarks of Microsoft Corp Netscape is a trademark of Netscape Communications Corporation Contacts Lantro...

Page 3: ...e that may cause undesired operation This device is intended only for OEM Integrators The OEM integrator should be aware of the following important issues Labeling of the End Product The end product t...

Page 4: ...er Input Characteristics RX RX ________________________15 100Base TX Transceiver Characteristics TX TX ___________________________15 Wireless Specifications ___________________________________________...

Page 5: ...2 3 Channel 1 Connections 11 Table 2 4 Channel 2 Connections 11 Table 2 5 Channel 2 RS 422 485 4 Wire Connections 11 Table 2 6 Channel 2 RS 485 2 Wire Connections 11 Table 2 7 WLAN Signals 13 Table 2...

Page 6: ...ded audiences are the engineers responsible for integrating the WiPort into their product Additional Documentation The following guides are available on the product CD and the Lantronix Web site www l...

Page 7: ...o a single compact module It includes a wireless connection an operating system an embedded Web server and a full TCP IP protocol stack In addition the WiPort sends email alerts and supports numerous...

Page 8: ...iption and Specifications WiPort Integration Guide 8 WiPort Block Diagram The following drawing is a block diagram of the WiPort showing the relationships of the components Figure 2 1 WiPort Block Dia...

Page 9: ...nd 12 Signal Ground 13 Reset In Resets the WiPort unit Reset In is low active Minimum reset pulse width is 2ms at IIL 500 A 14 CP0 Configurable pin 15 RTS1 Request to send hardware flow control output...

Page 10: ...Alternative Oupiin 2411 2X20GDN 017 not shrouded The mating connector is a 1mm micro header 40 pins 2 x 20 Serial Input Output The unit has two serial ports compatible with V24 serial standards at da...

Page 11: ...or Signal Description DB9 DB25 Signal DB9 DB25 Signal RXD1 Data In 2 3 RXD0 3 2 TXD1 TXD1 Data Out 3 2 TXD0 2 3 RXD1 RTS1 H W Flow Control Output 7 4 RTS0 8 5 CTS1 CTS1 H W Flow Control Input 8 5 CTS0...

Page 12: ...Description and Specifications WiPort Integration Guide 12 Sample Layouts for RS 485 Connectivity Figure 2 2 Combined RS 232 422 Transceiver Figure 2 3 Separate RS 232 422 Transceivers...

Page 13: ...wer LED is on continuously it indicates the radio is on and in normal mode When it is blinking it indicates the radio is in power saving mode WLAN Activity LED is also used to drive an external LED to...

Page 14: ...tings Table 2 10 Absolute Maximum Ratings Parameter Min Max Units Supply Voltage 3 0 3 6 V Input Voltage 0 5 6 V Output Voltage 0 5 6 V Operating Temperature 30 70 C Storage Temperature 40 85 C Recomm...

Page 15: ...S 0 5 ns Duty Cycle Distortion DCD 35 50 65 Overshot Undershot VOS 5 Jitter measured differentially 1 4 ns Ethernet LED1 LED2 current 8 8 14 1 17 0 mA Wireless Specifications Refer to the following ta...

Page 16: ...11b IEEE 802 11b PER 8 PER 8 Receiver Sensitivity 82 dBm for 11 Mbps 87 dBm for 5 5 Mbps 89 dBm for 2 0 Mbps 93 dBm for 1 0 Mbps 72 dBm for 54 Mbps 87 dBm for 11 Mbps 89 dBm for 5 5 Mbps 90 dBm for 2...

Page 17: ...P SMTP TFTP Management Internal web server SNMP read only Serial login Telnet login DeviceInstaller software Internal web server SNMP read only Serial login Telnet login DeviceInstaller software Inter...

Page 18: ...taller configuration software and Windows based Comm Port Redirector DeviceInstaller Web Manager Windows 98 NT 2000 XP based Device Installer configuration software and Windows based Comm Port Redirec...

Page 19: ...Specifications WiPort Integration Guide 19 Figure 2 7 Bottom View Recommended PCB Layout The hole pattern and mounting dimensions for the WiPort device server are shown in the following drawing Figure...

Page 20: ...ation label contains important information about your specific unit such as its product ID name bar code part number and MAC address Figure 2 9 Product Label The Dashboard must be used to provide an i...

Page 21: ...o serial ports DTE An on board Complex Programmable Logic Device CPLD drives status LEDs and configures external connections Note Either disregard WLAN POWER and WLAN ACTIVITY LEDs in the Ethernet Mod...

Page 22: ...485 2 Wire Connector WiPort Signal Description DB9 Pin Number TX RX Data Out In 7 TX RX Data Out In 3 Power Supply The evaluation board uses an external 3 3V regulated supply included with kit The ev...

Page 23: ...directly to each other through the PLD Can be used for loopback tests Note Other JP7 JP8 jumper configurations are not recognized by the CPLD at this time If using CPs for any combination of the abov...

Page 24: ...H RJ 45 with MAGNETICS and 2 LED s USB USB ANTENNA PWR SWITCH CPLD RXD1 ACTIVE LED TXD1 ACTIVE LED RXD0 ACTIVE LED TXD0 ACTIVE LED DB9 TXCVR LED PWR CONN POWER SUPPLY 3 3V WiPORT TEST HEADERS 2X10 2EA...

Page 25: ...0 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 J2 TSM 120 01 T DV RXD0 RXD1 CTS1 RTS0 TXD0 RTS0 TXD0 RXD1 RTS1 RTS1 CTS1 TXD1 TXD1 RSTIN TXD0 RXD0 ELED1 RESERVED CTS1 RESERVED RTS1 RTS0 ELED...

Page 26: ...1 SHUTDOWN 20 ONLINE 14 STATUS 11 RS232 U2 SP3223EUEA 3V3 RTS1_232 TX 485 RXD1_232 RX 485 TXD1_232 TX 485 DCD1_232 DTR1_232 CTS1_232 RX 485 1 2 C20 0 1uF 1 2 C13 0 1uF 1 2 C18 0 1uF 1 2 C21 0 1uF 1 2...

Page 27: ...8 42 I O19 43 GTS2_I O20 40 GSR_I O21 39 I O22 38 I O23 37 I O24 36 I O25 35 I O26 34 I O27 33 I O28 29 I O8 12 I O9 13 I O10 14 I O11 18 I O31 26 I O12 19 I O13 20 GCK1_I O 5 TCK 17 TMS 16 TDI 15 I O...

Page 28: ...dio For purposes of certification the WiPort was tested as a modular device CFR Title 47 FCC Part 15 Subpart B and C Class B FCC Module Approval FCC Identifier R68WIPORTG Industry Canada ICES 003 Issu...

Page 29: ...ip the replacement media to the customer In no event will Lantronix be responsible to the user in contract in tort including negligence strict liability or otherwise for any special indirect incidenta...

Reviews: