Installation Guide
SLC 8000 I/O Module
Module Extractor
1. Shut down the SLC 8000 either via the Web Manager or the Command Line Interface and unplug all power cords.
A) Web Manager
B) Command Line Interface
admin shutdown
DISCONNECT ALL POWER
CORDS ON THE SLC 8000
BEFORE INSTALLING THIS
MODULE TO AVOID
ELECTRICAL SHOCK. THE SLC
8000 MAY HAVE MORE
THAN ONE POWER SOURCE.
DO NOT HOT SWAP.
WHAT’S IN THE BOX
Note: When you use this command to shut down the SLC unit, the LCD front panel
displays "Shutting down the SLC," followed by a pause, and then "Shutdown
complete." When "Shutdown complete" displays, it is safe to power off the SLC
console manager. This command is not available on the web page.
2. Take out the filler panel if you are adding, or take out the existing module if you are replacing.
B) Using the Extractor (if the release lever is not accessible)
i)
Insert:
Insert it until the keys are behind the metal panel.
ii)
Pinch and pull:
Gently pinch the extractor from both sides
and pull until the I/O module is completely removed.
A) Using the Release Lever
i)
Press and pull:
Gently press the release lever
from underneath and pull the I/O module
until it is completely removed.
Release Lever
Keys
Metal Plate
Blade
Extractor
RJ45 Loopback Cable
INSTALL
GUIDE
Only for RJ45 I/O Module
BEFORE YOU INSTALL
THE I/O MODULE IS
ELECTROSTATIC-
SENSITIVE. ONLY
HANDLE AT A STATIC-
FREE WORKPLACE.
THE USB I/O MODULE
(FRUSB1601) REQUIRES
SLC 8000 FIRMWARE 7.2
OR ABOVE. DOWNLOAD
THE LATEST VERSION AT:
www.lantronix.com/
support/downloads
F/W