LSB4 Installation Guide
Set-up and Operation
3-15
Introduction
Set-up and
Operation
Customizing Serial Console Port Settings
The default characteristics of the serial console port are listed in
Figure 3-19.
Figure 3-19: Serial Port Default Characteristics
These settings can be changed using the
Set Port
and
Define Port
com-
mands. Some examples of Set/Define Port commands are shown below
[Figure 3-20]:
Figure 3-20: Set/Define Port Examples
To make Set Port commands permanent, use the
Save
Port
or the
Define
Port
command.
For information about the Save command, refer to the LSB4 Reference
Manual.
Local> LIST PORT
Port 1: Username: Physical Port 1 (Idle)
Char Size/Stop Bits: 8/1
Input Speed: 9600
Flow Ctrl: Xon/Xoff
Output Speed: 9600
Parity: None
Modem Control: None
Terminal Type: Soft
Characteristics:
Local> SET PORT SPEED 38400
Local> SET PORT FLOW XON
Local> SET PORT COMMAND ENABLED
NOTE
Summary of Contents for LSB4
Page 2: ...LSB4 Installation Guide For Lantronix LSB4 Ethernet Switch ...
Page 5: ...iii G Warranty Glossary Index ...
Page 6: ...iv ...
Page 13: ...Introduction LSB4 Installation Guide 1 6 Introduction ...
Page 28: ...3 Set up and Operation Installation Set up and Operation ...
Page 48: ...LSB4 Installation Guide Set up and Operation 3 20 Introduction Set up and Operation ...
Page 50: ...LSB4 Installation Guide Technical Support A 2 Introduction Technical Support ...
Page 62: ...LSB4 Installation Guide Pinouts C 6 Introduction Spanning Tree Pinouts ...
Page 83: ...LSB4 Installation Guide Warranty G 2 Introduction Warranty ...
Page 89: ...LSB4 Installation Guide Glossary Glossary vi Introduction Glossary ...