5: Commands and Levels
EDS-MD Command Reference
296
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter com-
mand mode.
<string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
Within {} specify decimal milliseconds time delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial port when
the
device boots and when the line is in command mode.
<string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default parity
Restores the default of no parity.
default protocol
Restores the default protocol on the line.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been re-
ceived, it will
be forwarded after this time since the last character.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level.
<line> = number of the line (serial port) to be configured.
name
<text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode signon message
Clears the signon message displayed at boot time and when
entering
command mode.
no gap timer
Removes the gap timer, so forwarding depends on the line
speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.