Installation
Is It Working?
2 - 7
When the unit is running normally, the OK LED blinks green once every
two seconds. If data is being transmitted on the Ethernet port, the OK
LED blinks yellow. The Serial LED blinks red when characters are
transmitted through the serial port, green when characters are received,
and yellow when characters are both transmitted and received.
2.3 Is It Working?
If the MSS appears to be working and the unit is connected to the
network, there are four ways to confirm that it is working correctly:
•
If there is a terminal attached, press the Return key and log in.
If you are able to log in, the server is running normally.
•
If an IP address has been configured for the MSS (see
IP
Address Configuration
on page 3-1), ping the MSS from a TCP/
IP host.
Figure 2-7:
Pinging the MSS
•
Perform a test using the Test command. See the
Commands
chapter in the
MSS Reference Manual
on CD-ROM for more
information.
When you are satisfied that the MSS is working properly, proceed to
Chapter 3,
Getting Started
. If the server does not boot properly, see
Appendix B,
Troubleshooting
.
unix% ping 192.0.1.233