To change the device switch mode to local, do the following:
1. Start a USB session (see “
Starting a USB Session
”).
2. At the command prompt type
set switch mode=local
.
3. Press the
Enter
key.
4.
Reboot the card for the changes to take effect. At the command prompt type
reboot
.
Doing a reboot, restart or upgrade of the IONMM, a power restart of the chassis, or a reset
to factory removes temporary files (e.g. configuration backup files, Syslog file). A Factory Reset also
removes the permanent settings (e.g. configuration files, HTTPS certification file, SSH key).
5. Press the
Enter
key to reboot the module.
6. At the command prompt type
show switch mode
.
7. Press the
Enter
key. This displays the device’s management mode - local or remote - indicating
where the device is managed:
•
local
– device is managed through direct connection to the device.
•
remote
– device is managed through the IONMM.