11
for Authentication*
IGMP
Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query
Multicast VLAN Registration
MVR enables multicast packets go through VLAN for VOD application
Bandwidth Control
Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast
packet only and all types of packet.
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet
limit.
PTP v2 & RTC
Support hardware-based IEEE1588 PTPv2 in 1
μs with 4 x GigaT ports
Built-in RTC(Real Time Clock) to keep track of time
Flow Control
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex
Environmental Monitoring
System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status
System Log
Supports System log record and remote system log server
SMTP/Text SMS
Supports SMTP Server and 6 e-mail accounts for receiving event alert; can send SMS text alert via mobile
Relay Alarm
Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V
Protection
Miss-wiring avoidance
Repowered auto ring restore (node failure protection)
Loop protection
SNMP Trap
Up to 3 trap stations; trap types including:
Device cold start
Authorization failure
Port link up/link down
PoE port event
Abnormal environmental monitoring
DHCP
Provide DHCP Client/ DHCP Server/ relay Option 82*
DNS
Provide DNS client feature and support Primary and Secondary DNS server.
SNTP
Supports SNTP to synchronize system clock in Internet
Firmware Upgrade
Firmware upgrade via TFTP or Lantech InstaConfig**
Configuration
upload and download
Supports text configuration file for system quick installation
IfAlias
Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface
*Future release
**Optional
Summary of Contents for IPES-5408T
Page 16: ...14 2 2 Package Content Manual CD Product Console cable...
Page 21: ...19 Off No device attached...
Page 28: ...26 4 3 Multiple Rings...
Page 29: ...27 4 4 Dual Homing 4 5 Chain...
Page 30: ...28...
Page 56: ...54 C You can set the forwarding method of port break event in here...
Page 69: ...67 Demo Demo display each topology in different connection...
Page 93: ...91 6 15 2 3 Remember to press Apply 6 15 2 4 Save setting...
Page 107: ...105 The setting of neighbour switch The setting of none switch...