Page 2: ...nt Plate Mounting 11 3 4 Wiring the Power Inputs 12 3 5 Wiring the Fault Alarm Contact 13 3 6 Cabling 14 Chapter 4 Console Management 18 4 1 Connecting to the Console Port 18 4 2 Pin Assignment 18 4 3...

Page 3: ...5 11 Port Configuration 39 5 12 Port Status 40 5 13 Port Statistics 41 5 14 Port Port Alert 42 5 15 Rate Control Rate Limit 43 5 16 Spanning Tree 45 6 18 1 RSTP Setting 45 6 18 2 RSTP Information 47 5...

Page 4: ...ource Guard Configuration 56 6 26 2 IP Source Guard Static Table 57 6 27 Maintenance 58 6 27 1 Save Configuration 58 Troubles shooting 63 Appendix A RJ 45 Pin Assignment 64 RJ 45 Pin Assignments 64 RJ...

Page 5: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 6: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 7: ...ES 2204F 4 10 100TX 2 100M SFP 9 5 60VDC 40 75 C Management SNMP v1 v2c v3 Web Telnet SNMP MIB RFC 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RST...

Page 8: ...cket filter rate can be set from 100K 102400Kbps 10 100 100K 256000Kbps 1000 Flow Control Supports Flow Control for Full duplex and Back Pressure for Half duplex System Log Supports System log record...

Page 9: ...3 ifAlias Each port allows importing 128bits of alphabetic string of word on SNMP interface...

Page 10: ...against the checklist Managed Industrial Switch x 1 User manual x 1 Pluggable Terminal Block x 1 RJ 45 to DB9 Female cable x 1 Compare the contents of the industrial switch with the standard checklist...

Page 11: ...Hardware Description 2 1 Bottom View The bottom panel of the Industrial Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm Bottom Panel of the indust...

Page 12: ...em and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for the switch LED Color Status Meaning...

Page 13: ...g The port is transmitting or receiving packets from the TX device Off No device attached P1 P4 Green On A network device is detected Blinking The port is transmitting or receiving packets from the TX...

Page 14: ...section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare t...

Page 15: ...is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps...

Page 16: ...sert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track revers...

Page 17: ...switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use th...

Page 18: ...contacts 1 and 2 for power 1 or 5 and 6 for power 2 Tighten the wire clamp screws for preventing the wires from loosing IPES 2204F 48V 45 56VDC IPES 2204F 48V E 45 56VDC IPES 2204F 12V 9 5 56VDC IPES...

Page 19: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Page 20: ...s the auto detected Giga port Gigabit Copper SFP combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for the connection up to 1000Mbps The small form factor...

Page 21: ...llow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Transceiver to the SFP module Transceiver Inserted Second insert t...

Page 22: ...16 LC connector to the transceiver...

Page 23: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Page 24: ...Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program 4...

Page 25: ...le port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up...

Page 26: ...Management The system supports the console management CLI command After you log in on to the system you will see a command prompt To enter CLI management interface type in enable command CLI command...

Page 27: ...anagement supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen 5 2 Prep...

Page 28: ...ress of the switch and then Press Enter 3 The login screen will appear right after 4 Key in the user name and password The default user name and password are the same as root 5 Press Enter or click th...

Page 29: ...cribes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization System OID SNMP OID of switch Firmw...

Page 30: ...times the user was worry about that Could my switch process too many network packets So the network throughput was keeping decreasing In this option you can monitor the CPU of switch to see if the swi...

Page 31: ...ght saving time DST is the convention of advancing clocks so that afternoons have more daylight and mornings have less Typically clocks are adjusted forward one hour near the start of spring and are a...

Page 32: ...iddle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4...

Page 33: ...riod and Daylight Saving Offset again Daylight Saving Period Set up the Daylight Saving beginning date time and Daylight Saving ending date time Please key in the value in the format of YYYYMMDD and H...

Page 34: ...login user name and password for the management security issue User name Type in the new user name The default is root New Password Type in the new password The default is root Confirm password Re typ...

Page 35: ...the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabled this switch is configured as a DHCP client The network DHCP server will assi...

Page 36: ...30 IP Addressing interface...

Page 37: ...uration Syslog Configuration interface Syslog Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch b...

Page 38: ...es from network devices implementing SNMP SNMP Agent Agent Mode Select the SNMP version V1 V2c or V3 that you want to use it And then click Change to switch to the selected SNMP version mode SNMP V1V2...

Page 39: ...33 SNMP Agent Configuration interface...

Page 40: ...n as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version Server IP Enter the IP address of the trap manager Community Enter the community string for t...

Page 41: ...the failure detection Power Failure Setting Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails Port Link Down Broken Setting Tick the check box to ena...

Page 42: ...ess format e g switch101 123 com to identify where the e mail alert comes from Mail Subject Input the subject of Email Authentication Having ticked this checkbox the mail account password and confirm...

Page 43: ...ely by setting the trigger condition System event selection There are 3 event types Device Cold Start Authentication Failure and X ring Topology Change The checkboxes are not available for ticking unl...

Page 44: ...38 Event Configuration interface...

Page 45: ...t speed and negotiated way manually Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rat...

Page 46: ...40 5 12 Port Status It will show you the status of port configuration setting...

Page 47: ...en the collision or heavy traffic occurs Port The port number Type Displays the current speed of connection to the port Link The status of linking Up or Down State It s set by Port Control When the st...

Page 48: ...ntication Failure When the SNMP authentication fails the system will issue the event log email alert to the system log SMTP server respectively MAC Violation When the MAC address has violated the syst...

Page 49: ...control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate...

Page 50: ...Unicast Broadcast Multicast Broadcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type And then...

Page 51: ...The value must be a multiple of 4096 according to the protocol standard rule Max Age The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attemp...

Page 52: ...ows the P2P status of the link to be manipulated administratively True means the port is regarded as a point to point link False means the port is regarded as a shared link Auto means the link type is...

Page 53: ...47 6 18 2 RSTP Information This web page provides the port and switch information about RSTP RSTP System Configuration interface...

Page 54: ...itch as Enable or Backup Enable means this switch will play the role of root switch Backup means this switch will take over the role of root switch when the original root switch fail Port setting set...

Page 55: ...ation about themselves to other nodes on the network and store the information they discover LLDP runs on all 802 media The protocol runs over the data link layer only allowing two systems running dif...

Page 56: ...50 6 22 1 LLDP Neighbors It will show you the information about Port Neighbor via LLDP protocol...

Page 57: ...affic from the ones of the same VLAN Basically creating a VLAN on a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices...

Page 58: ...oose to use an 8 4 2 1 queuing scheme or a strict priority scheme or select the priority type to configure QoS policy Qos Policy Select the QoS policy rule Using the 8 4 2 1 weight fair queue scheme T...

Page 59: ...own selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port Port x Each port has 4 priority levels High Midd...

Page 60: ...l With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port COS priority Set up the...

Page 61: ...evel has 4 types of priority High Middle Low and Lowest The default value is Lowest priority for each level When the IP packet is received the system will check the DSCP level value in the IP packet t...

Page 62: ...eckboxes and the ten security IP column fields will then be available If not those items will appear in grey Enable HTTP Server Having ticked this checkbox the devices whose IP addresses match any one...

Page 63: ...r access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet service once IP Security Mode is enabled And then click Apply to have the configuration take effec...

Page 64: ...Save Configuration Save the current setting of switch 6 27 2 Restart Device Make the switch warm start 6 27 3 Factory Defaults Reset switch to default configuration Click Reset to reset all configura...

Page 65: ...Upgrade TFTP Server IP Address Type in your TFTP server IP Firmware File Name Type in the name of the firmware image file to be updated Click Upgrade You can also browser the firmware on your hard dr...

Page 66: ...erver IP Address Type in the TFTP server IP Restore File Name Type in the correct file name for restoring Click Restore You can back up the current configuration from flash ROM to the TFTP server for...

Page 67: ...Specify the SFP port and show the SFP module information Temperature Display the internal temperature of the SFP default threshold and present value Vcc Display the supply voltage of the SFP default...

Page 68: ...of the SFP default threshold and present value RX PWR Display the received power of the SFP default threshold and present value Syslog SMTP The port will send an e mail or log on local to administrat...

Page 69: ...length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which...

Page 70: ...d crossover cable schematic 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data RJ 45 Pin Assignments Pin Number Assignment 1...

Page 71: ...ng two figures show the 10 100Base TX cable schematic Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45...

Page 72: ...66 Straight through cables schematic Cross over cables schematic...

Page 73: ...ransmitting data and pins 3 and 6 for receiving data pins 4 5 7 and 8 are used for power supplying Pin out of Cisco non 802 3af standard PD Pin Signal 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC Pin o...

Page 74: ...X VCC 7 8 Note and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise you m...

Page 75: ...69...