4.  Maintaining support with your right 

thumb, take the scale in your left hand 

and pull to the left keeping the scale 

level and parallel to the load.

 

Important note: For proper results, 

the tool must be vertical and the 

scale must be level. 

(See Photo - 6) 

5.  Pull the scale to the left as shown in 

Photo - 6, 

so the tool rotates around 

the fulcrum finger until the indicator

 

foot makes contact with or “kisses”

 

the 

film

, not the load.

 

(Refer to Photos 7 & 8)

 

6.  When contact is made, note the 

reading on the scale. Make sure the 

reading has lbs. and oz. on the right 

side of the digital readout.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.  Repeat the procedure for the middle, starting

 

from the right side at approx. half the height of

 

the load. 

(See Photo - 9)

Photo - 6 Supporting top plate with your thumb pull scale left and parallel

Photo - 7 Right Way

Photo - 8 Wrong Way

Photo - 9 Measure the middle of the load

“Kiss” the film

Touching load

Middle of 

the load

22”

Indicator 

line 

perpendicular 

to load

Indicator 

line not 

perpendicular 

to load

Reviews: